PCE Instruments PCE-W3 Manual
Read below 📖 the manual in Italian for PCE Instruments PCE-W3 (3 pages) in the Measuring equipment category. This guide has been helpful for 3 people and has been rated 4.5 stars on average by 2 users
Page 1/3
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
MANUAL
Moisture Analyser
PCE-W3
1. Application
Moisture Meter for Waste Paper is designed to rapidly det ermine the level of moisture contents of waste paper.
2. Operation principle
Moisture meter measures the resistance of the m ate rial (waste paper). It has b een calibrated for normal
composition of waste paper.
3. Technical data
Range 6% - 30%
Power 9V, 1 battery 6F22
Electrode length 85 mm
Size 80 * 180 * 250 mm
Limitations
This warranty becomes null and void if you fail to pack your PCE-W3 in a manner consistent with the original
product packaging and dam-age occurs during pr uct shipment. This warranty does not cover: circumstance od
beyond our company’s control; service r equired as the result of unauthorized modiÿcations or service; misuse,
abuse; failure to follow our com pany operating or main tenance instructions. Repai r or replacement without
charge is our company’s only obligat ion under thi s warranty. Our comp any will not be res ponsible for any
special, consequential or incidental damages resulting fr om the purchase, use, or im proper functioning of this
equipment regardless of the cause. Such damages for which our company’s will not be responsible include, but
are not limited to, loss of revenue or proÿt, downtime cost s, loss of use of the equipment, cost of any substitute
equipment, facilities of services, or claims of your customers for such damages.
GUA N RA TEE
The manufacturer guarantees the correct functioning of the Moisture Meter for Waste Paper PCE-W3 under
normal use for a period of 12 months.
NOTE: "This instrument doesn’t have ATEX protection, so it should not be used in potentially explosive
atmospheres (powder, ˜ammable gases)."
4. Measurements
Conduct the measurements of moisture contents of waste paper following these steps:
• take the device out of its case and remove the protective cap,
• connect the device with the electrode using the wire provided,
• turn the power on,
• slide the electrode into the waste paper (if it’s compressed) or firmly press the electrode against
a single piece of waste paper,
• read the result,
• repeat the measurement with at least 3 randomly selected samples,
• the final result is an average of all the measurements,
• turn the power off.
WARNING:
The measuring range of the device is 6% - 30%. Moisture contents below 6% is indicated as „LO”.
Results over 30% should be considered as rough estimates.
5. Changing the battery and storage
The device is equipped with a power level control circuit. When the power drops below acceptable level a sign ”LO BAT”
appears on the left side of the LCD. This indicates that the battery has expired and should be replaced with a new one.
To replace the battery unscrew the screw on the back of the instrument and carefully remove the back panel. Store the
device in a dry place.
NOTE: "This instrument doesn t ha’ ve ATEX protection, so it should not be used in potentially explosi e v
atmosp
Product Specifications
Brand: | PCE Instruments |
Category: | Measuring equipment |
Model: | PCE-W3 |
Do you need help?
If you need help with PCE Instruments PCE-W3, ask a question below and other users will answer you
Measuring equipment PCE Instruments User Manuals
24 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
Measuring equipment User Manuals
- Measuring equipment EBERLE
- Measuring equipment Hazet
- Measuring equipment Fluke
- Measuring equipment Megger
- Measuring equipment Kogan
- Measuring equipment AkYtec
- Measuring equipment Voltcraft
- Measuring equipment Klein Tools
- Measuring equipment PeakTech
- Measuring equipment Clean Air Optima
- Measuring equipment Flex
- Measuring equipment CSL
- Measuring equipment Elgato
- Measuring equipment Kern
- Measuring equipment Be Cool
- Measuring equipment ORNO
- Measuring equipment Einhell
- Measuring equipment Mitsubishi
- Measuring equipment Noyafa
- Measuring equipment Megasat
- Measuring equipment Reely
- Measuring equipment Joy-it
- Measuring equipment Logilink
- Measuring equipment Basetech
- Measuring equipment Gossen Metrawatt
- Measuring equipment TFA
- Measuring equipment Owon
- Measuring equipment Extech
- Measuring equipment Milesight
- Measuring equipment Sonel
- Measuring equipment Flir
- Measuring equipment Testo
- Measuring equipment MSW
- Measuring equipment Stamos
- Measuring equipment Ideal
- Measuring equipment Hikmicro
- Measuring equipment Siglent
- Measuring equipment Kopp
- Measuring equipment PICO
- Measuring equipment Enda
- Measuring equipment Wachendorff
- Measuring equipment Ermenrich
- Measuring equipment Beha-Amprobe
- Measuring equipment Adwa
- Measuring equipment Tempo
- Measuring equipment Vemer
- Measuring equipment Testboy
- Measuring equipment Duro Pro
- Measuring equipment Kyoritsu
- Measuring equipment Benning
- Measuring equipment MASIMO
- Measuring equipment Stahlwille
- Measuring equipment SHX
Latest Measuring equipment User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024