PCE Instruments PCE-DC 41 Manual

Read below đź“– the manual in Italian for PCE Instruments PCE-DC 41 (12 pages) in the Measuring equipment category. This guide has been helpful for 9 people and has been rated 4.5 stars on average by 2 users

Page 1/12
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
www.pce-instruments.com/english
www.pce-instruments.com
Manual
AC/DC Clamp Meter PCE-DC 41
Version 1.1
Date of creation: 07.07.2015
Date of last change: 05.08.2015
Manual
2
Content
1 Introduction ............................................................................................................. 3
2 Safety notes ............................................................................................................. 3
2.1 Warning symbols ........................................................................................................................ 3
2.2 Safety instructions ...................................................................................................................... 3
3 Specications .......................................................................................................... 4
3.1 General ....................................................................................................................................... 4
3.2 Electrical ..................................................................................................................................... 5
4 System description ................................................................................................. 6
4.1 Display ........................................................................................................................................ 6
4.2 Front and rear ............................................................................................................................. 7
4.3 Key functions .............................................................................................................................. 7
4.3.1 HOLD function ................................................................................................................................ 7
4.3.2 PEAK function ................................................................................................................................ 7
4.3.3 Zero function .................................................................................................................................. 7
4.3.4 Backlight function ........................................................................................................................... 7
5 Instructions .............................................................................................................. 8
5.1 Measurement .............................................................................................................................. 8
5.1.1 AC voltage measurement 8..............................................................................................................
5.1.2 DC voltage measurement .............................................................................................................. 8
5 AC current measurement .1.3 ............................................................................................................... 9
5.1.4 DC current measurement ............................................................................................................... 9
5.1.5 Resistance measurement ............................................................................................................ 10
5.1.6 Continuity test with buzzer ........................................................................................................... 10
5.2 Battery replacement ................................................................................................................. 11
5.3 Maintenance ............................................................................................................................. 11
5.4 Cleaning .................................................................................................................................... 11
6 Contact ................................................................................................................... 12
6.1 PCE Instruments UK ................................................................................................................ 12
6.2 PCE Americas .......................................................................................................................... 12
Manual
3
1 Introduction
Thank you for purchasing a PCE-DC 41 from PCE Instruments.
This instrument is highly versatile in power system maintenance as it has several functions. It is not only
very reliable in measuring power, it can also measure voltage, current and continuity at high accuracy.
Measurement results are easily readable from the 4-digit LC display with backlight. The device’s special
features are its Peak Hold and Data Hold functions, its Auto Zero function as well as an Auto Power O
function which turns o the meter after 30 minutes of inactivity. The instrument comes with batteries, a
test lead, a carrying case and an instruction manual.
2 Safety notes
2.1 Warning symbols
Attention! Please refer to instruction manual.
Dangerous voltage may be present at terminals.
Double insulation.
2.2 Safety instructions
Please read this manual carefully and completely before you use the device for the first time. The device
may only be used by qualied personnel and repaired by PCE Instruments personnel. There is no
warranty of damages or injuries caused by non-observance of the manual.
- The device may only be used the approved temperature and humidity range. in
Operat ing conditions: 0 … 40 °C (32 … 104 °F); ˂70 % RH
Storage conditions: - 10 … 60 °C (14 … 140 °F); ˂80 % RH
- Inspect the device as well as the test leads before each use. If there is any visible damage, do not use
the device.
- Make sure that the main function dial is in the correct position before each measurement.
- Do not carry out any resistance or continuity tests on a live power system.
- Do not apply voltage between the test terminals or a test terminal to ground exceeding the maximum
limit as specied in this manual.
- Keep your ngers behind the protection ring when using the test lead for measurement.
- To ensure high accuracy, replace the battery whenever the icon appears.
- The case should only be opened by qualied personnel of PCE Instruments.
- The instrument should never be placed with the user interface facing an object ( keyboard side e.g. on a
table ).
- You must not make any technical changes the device. to
- The appliance should only be cleaned with a dry cloth. / Do not use any abrasives or solvents.
This manual is published by PCE Instruments without any guarantee.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please ntact PCE Instruments. co

Product Specifications

Brand: PCE Instruments
Category: Measuring equipment
Model: PCE-DC 41

Do you need help?

If you need help with PCE Instruments PCE-DC 41, ask a question below and other users will answer you




Measuring equipment PCE Instruments User Manuals

Measuring equipment User Manuals

Latest Measuring equipment User Manuals

PeakTech

PeakTech 3730 Manual

27 October 2024
Klein Tools

Klein Tools TI270 Manual

27 October 2024
Klein Tools

Klein Tools TI290 Manual

27 October 2024
Klein Tools

Klein Tools TI220 Manual

27 October 2024
PeakTech

PeakTech 4200 Manual

27 October 2024
PeakTech

PeakTech 3203 Manual

27 October 2024
PeakTech

PeakTech 1890 Manual

27 October 2024
PeakTech

PeakTech 2705 Manual

27 October 2024
PeakTech

PeakTech 4145 Manual

27 October 2024
PeakTech

PeakTech 4130-1 Manual

27 October 2024