1. Functional oveiew
Radiation individual alarm device is collocated with highly exible
Geiger counting pipe as detector;it is mainly responsible for
monitoring the radiation of X, y and hard β ray in various radioactive
work areas; it is featured as swift response and broad measurement
scope; It is able to display the dosage equivalent rate it is widely
applied in the individual safety protection monitor and
radioactive indication for work personnel in the following
elds:nuclear power plant, accelerator, iron & steel indust, chemical
indust, isotope application, industrial X and y non-destructive aw
detection, radioactive medical treatment, Cobalt soure treatment, y
radiation, radioactive laborato and surrounding environment
monitor of nuclear facilities.
2.Features
1. Monitor X, gamma and hard beta rays.
2. With high sensitivity, the instrument can also measure the
environment background.
3.Inteace using all of Chinese,Traditional Chinese and English.
4.Graphic LCD with adequately big screen.
5.Optional alarm modes including sound/vibration.
3.Technological Parameters
1.Radiation Detection: X, gamma and hard betarays
2.Detector: energy compensation GM tube(Geiger counter tube)
3.Normal content standard within 0.5μs V/h
4.Measurement range
Dose equivalent rate: 0.00-1000uSV/h(maximum 10mSv/h)
5. Energy range: 48 ke V-1.5 MeV ≤±30% (for137Cs-)
6.Sensitivity: 80 CPM /μSw/h(for Co-60)
7. Measurement display: the dose rate display will update eve
second and the protect alarm display is shoer than 5 seconds.
8.Operating environment: temperature -10℃
~+45℃. Relative humility:≤95%(+45℃)
9.Dimensions:143×77×28mm
4. General Operation Method
1.Staup
Prepare 2 AA batteries; Since with batteries installed, press and hold
【O】button for 3seconds and the instrument will sta up. TheLCD
display is as the following gure:
5. Parameter setting
The parameters that can be modied by the user include: system time,
system information, automatic shutdown, and language setting. The
corresponding parameters can be modied through the keyboard.
Back
Select
Move Options
Refresh
Menu
Alarm Settings
1)Shutdown
Press and hold 【O】 button for 3 seconds,
and the instrument will shut down.
2)Measurement
The instrument will be in measurement mode since staup. There are
two measurement values: one is dose rate with units of μSv/h,uGy/h,
mR/h, cps and cpm;the other one is accumulated dose,which is the
accumulative value of dose rate for some time, with units of μSv or
mSv. The instrument will ring an alarm as the preset alarm mode when
a type of value exceeds the set alarm threshold.
3)Refresh: Press the 【O】 key to resta the device for testing.
4)Alarm settings: audible alarm, vibration alarm
5)Instructions for LCD Display Data This information displayed on this
instrument is as follows:
Relevant Knowledge for Radioactive Unit
6、 Conversions
I. International standard(our count implement this
standard) 1990
1.Radioactive sta: 20mSv/a
2.General Public: 1mSy/a
Note: the standard above is according to ICRP
suggestions and GB-492-84 regulations.
II. Knowledge for Unit Conversions and Etc
IsV/h=100R/h
InCkg-1/h=4μG/h
Radon Unit: 1Bp/L=0.27em=0.27x10^(-10)
Ci/L
III. Calculation for Decay Value of Radioactive
Isotopes
A=A0e﹣λτ 1=1n2/T1/2
T1/2 is half-time period
A0 is the known source strength
A is the strength after the time of t
Calculate the radiation shielding by checking
Radioactive
Have and 1/10 value (cm)of different materials
Radioactive
Source Lead Ferrum Concrete
halve 1/10 halve 1/10 halve 1/10
Cs-137 0.65 2.2 1.6 5.4 4.9 16.3
Ir-192 0.55 1.9 1.3 4.3 4.3 14.0
Co-60 1.10 4.0 2.0 67 6.3 20.3
8.Accessories List
Item
Radiation Meter
User Manual
USB-C C able
Instrument box
Quantity
1
1
1
1
9, Notice
Radiation individual alarm is a precise
instrument. Please protect it carefully. The following suggestions are
for the maintenance and life extending of the instrument.
a、Keep it dries as much as possible in the process of storage and use,
and too much moisture will cause the instrument damage.
b、Do not drop. knock or severely shake the detector, or it will cause
damages of this detector.
c、Remove the batte when the instrument is not used for a long
period of time. If the instrument dose not work properly.
The company resees the right to theimprovement of product
peormance ormodication of the manual without priornotice to
users.
10、 Safe Operation Norms
Please read the manual carefully. Itmay cause the improper working of
the instrument if the user doesn't operate following the manual.
Please apply standard AA batteries or rechargeable batteries.
Without accepted any rebuild or maintenance may cause damages of
this instrument.
When at work, if you suspect that the instrument may be malfunction,
please turn o the instrument and quickly with draw the hazardous
location. Contact the manufacturer as soon as possible.
Notice:
The company has the nal right to interpret this manual. The company
resees the right to improve product peormance and modify this
manual without prior notice to users.
Note: Ra-226(t=1608 year)r=0.825Rm2/hr.cr
Cs-137(t=29.9year)r=0.33R.m2/hr.cr
Co-60(t=5.23year)r=1.32R.m2/hr.cr
IV.Relationship between Radioactive Resource and Distance
The strength of the radioactive source is ininverse propoion of the
square of the distance.
X= A.r/R2
A:the activity of point radioactive source;
R: the distance to the source;
r: the constant of exposure rate
1μR/h=lγ(the former used unit for mineral
search of nuclear indust)
Radioactivity:
1Ci=3.7x 10^10Bp=37GBq
ImCi=3.7x10^7Bp=37MBq
1Ci=3.7x10^4Bp=37KBq
1Bp=2.703x10^(-11)Ci=27.03pci
Dose equivalent:
ISv= 10^3mSv=10^6μSV
I Sv=100rem
100urem=lμSy
Exposure Dose:
1R=10^3mR=10^6μR
1R=2.58×10^(-4)Ckg -1
Absorption Dose:
1Gy=10^3mGy=10^6μGy
1Gy=100rad
The Others:
1Sv=1Gy 1g Radium=0.97Ci≈1Ci
Product Specifications
Brand: | PCE Instruments |
Category: | Measuring equipment |
Model: | PCE-RAM 6 |
Do you need help?
If you need help with PCE Instruments PCE-RAM 6, ask a question below and other users will answer you
Measuring equipment PCE Instruments User Manuals
24 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
Measuring equipment User Manuals
- Measuring equipment EBERLE
- Measuring equipment Hazet
- Measuring equipment Fluke
- Measuring equipment Megger
- Measuring equipment Kogan
- Measuring equipment AkYtec
- Measuring equipment Voltcraft
- Measuring equipment Klein Tools
- Measuring equipment PeakTech
- Measuring equipment Clean Air Optima
- Measuring equipment Flex
- Measuring equipment CSL
- Measuring equipment Elgato
- Measuring equipment Kern
- Measuring equipment Be Cool
- Measuring equipment ORNO
- Measuring equipment Einhell
- Measuring equipment Mitsubishi
- Measuring equipment Noyafa
- Measuring equipment Megasat
- Measuring equipment Reely
- Measuring equipment Joy-it
- Measuring equipment Logilink
- Measuring equipment Basetech
- Measuring equipment Gossen Metrawatt
- Measuring equipment TFA
- Measuring equipment Owon
- Measuring equipment Extech
- Measuring equipment Milesight
- Measuring equipment Sonel
- Measuring equipment Flir
- Measuring equipment Testo
- Measuring equipment MSW
- Measuring equipment Stamos
- Measuring equipment Ideal
- Measuring equipment Hikmicro
- Measuring equipment Siglent
- Measuring equipment Kopp
- Measuring equipment PICO
- Measuring equipment Enda
- Measuring equipment Wachendorff
- Measuring equipment Ermenrich
- Measuring equipment Beha-Amprobe
- Measuring equipment Adwa
- Measuring equipment Tempo
- Measuring equipment Vemer
- Measuring equipment Testboy
- Measuring equipment Duro Pro
- Measuring equipment Kyoritsu
- Measuring equipment Benning
- Measuring equipment MASIMO
- Measuring equipment Stahlwille
- Measuring equipment SHX
Latest Measuring equipment User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024