PCE Instruments PCE-PH 22 Manual
PCE Instruments
Measuring equipment
PCE-PH 22
Read below 📖 the manual in Italian for PCE Instruments PCE-PH 22 (11 pages) in the Measuring equipment category. This guide has been helpful for 4 people and has been rated 4.5 stars on average by 2 users
Page 1/11
Manual
PCE-PH 22Water Analysis Meter
Date o last change: 07.07.2016f
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
Manual
2
Contents
1 Introduction ............................................................................................................. 3
2 Safety notes ............................................................................................................. 3
3 Specification ............................................................................................................ 4
4 System description ................................................................................................. 5
5 pH Calibrating procedure ....................................................................................... 6
5.1 Calibrating Consideration ........................................................................................................... 6
5.2 Requiring Equipment for Calibration 6..........................................................................................
5.3 Calibration procedures 6...............................................................................................................
6 Measuring Procedure 7 ..............................................................................................
6.1 pH measurement ........................................................................................................................ 7
6.2 Data Hold .................................................................................................................................... 7
6.3 Data Record (Max., Min. reading) .............................................................................................. 7
6.4 Change Temp. unit °C, °F .......................................................................................................... 7
7 Data Logger ............................................................................................................. 8
7.1 Save data 8....................................................................................................................................
7.2 Call data 8......................................................................................................................................
7.3 Delete data (Empty the memory) 9...............................................................................................
8 Replacement of Battery .......................................................................................... 9
9 Replacement of pH Electrode ..............................................................................10
10 Disposal ................................................................................................................. 11
11 Contact ................................................................................................................... 11
11.1 PCE Instruments UK ................................................................................................................ 11
11.2 PCE Americas .......................................................................................................................... 11
Manual
3
1 Introduction
Thank you for purchasing a -Meter from PCE Instruments. PH
The water resistant PCE-PH 22 pH meter quickly detects the pH value and temperature. Thanks to its
split display it can show the pH value and temperature reading simultaneous with this pH meter. Its
durable enclosure is water resistant up to IP 67 and can be used in adverse weather conditions.
Recalibration of the device always ensures that readings are accurate and it is easy to do with the help of
the calibration kit. The automatic calibration is done via the keypad and without the need for calibration
screws. This pH meter has an electrode integrated into its enclosure and the readings are adjusted
automatically for temperature compensation.
2 Safety notes
Please read this manual carefully and completely before you use the device for the rst time. The device
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no
warranty of damages or injuries caused by non-observance of the manual.
- The device may only be used approved temperature range in
-
The opening the case should only be done by qualied personnel of the PCE Instruments. of
- The instrument should never be placed with the user interface (e.g. keyboard side on a table )
- You should not make technical changes the device on
- The appliance should only be cleaned with a damp cloth / use only -neutral cleanerpH
This user's handbook is published from PCE Instruments without any guarantee.
We expressly point to our general guarantee terms, they can be found in our general terms of business.
If you have any questions please ntact PCE Instruments. co
Product Specifications
Brand: | PCE Instruments |
Category: | Measuring equipment |
Model: | PCE-PH 22 |
Do you need help?
If you need help with PCE Instruments PCE-PH 22, ask a question below and other users will answer you
Measuring equipment PCE Instruments User Manuals
24 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
22 October 2024
Measuring equipment User Manuals
- Measuring equipment EBERLE
- Measuring equipment Hazet
- Measuring equipment Fluke
- Measuring equipment Megger
- Measuring equipment Kogan
- Measuring equipment AkYtec
- Measuring equipment Voltcraft
- Measuring equipment Klein Tools
- Measuring equipment PeakTech
- Measuring equipment Clean Air Optima
- Measuring equipment Flex
- Measuring equipment CSL
- Measuring equipment Elgato
- Measuring equipment Kern
- Measuring equipment Be Cool
- Measuring equipment ORNO
- Measuring equipment Einhell
- Measuring equipment Mitsubishi
- Measuring equipment Noyafa
- Measuring equipment Megasat
- Measuring equipment Reely
- Measuring equipment Joy-it
- Measuring equipment Logilink
- Measuring equipment Basetech
- Measuring equipment Gossen Metrawatt
- Measuring equipment TFA
- Measuring equipment Owon
- Measuring equipment Extech
- Measuring equipment Milesight
- Measuring equipment Sonel
- Measuring equipment Flir
- Measuring equipment Testo
- Measuring equipment MSW
- Measuring equipment Stamos
- Measuring equipment Ideal
- Measuring equipment Hikmicro
- Measuring equipment Siglent
- Measuring equipment Kopp
- Measuring equipment PICO
- Measuring equipment Enda
- Measuring equipment Wachendorff
- Measuring equipment Ermenrich
- Measuring equipment Beha-Amprobe
- Measuring equipment Adwa
- Measuring equipment Tempo
- Measuring equipment Vemer
- Measuring equipment Testboy
- Measuring equipment Duro Pro
- Measuring equipment Kyoritsu
- Measuring equipment Benning
- Measuring equipment MASIMO
- Measuring equipment Stahlwille
- Measuring equipment SHX
Latest Measuring equipment User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024