Owon CP024 Manual
Owon
Measuring equipment
CP024
Read below 📖 the manual in Italian for Owon CP024 (4 pages) in the Measuring equipment category. This guide has been helpful for 7 people and has been rated 4.5 stars on average by 2 users
Page 1/4

MODEL: CP024
AC/DC CLAMP CURRENT PROBE
1、
、
、
、、INTRODUCTION
The is a mini size clamp current probe. It can convert the test current into a
voltage output. As an adapter of the oscilloscope, it is very convenient to use
this probe to test AC or DC current in any conductor.All ranges are selected by
toggle switch, easy to operate.It is an ideal tester for maintenance and
inspection work on all types of electrical equipment.
2、
、
、
、、SAFETY INTRODUCTIONS
Please according to the method of using this manual before operating
equipment, in case the instrument damage.
To maintain the instrument use safety, please do not test beyond the
prescribed current.
Do not use a broken probe signal output line.
When testing working voltage higher than 60 VDC or 30 vac line, please be
careful to use.
Operating environment condition:
1. Secondary safety insulation
2. Secondary pollution
3. Suitable for indoor use
4. Relative humidity below 70%RH
5. Operating temperature: 0C to 40C
Maintenance Essentials:The inspection and maintenance detailed in this
manual shall be handled by professionally qualified maintenance personnel.
Essentials of cleaning:Clean with dry cloth, do not use stain remover, solvent
clean this probe.
Safety symbols description:
Caution, risk of danger (refer to this manual for
specific Warning or Caution information)
Equipment protected throughout by double
insulation or reinforced insulation
Conforms to European Union directives
3、
、
、
、、Specification

3.1 GENERAL Specification
RANGE:
:
:
::4A,40A,400A
Minimum resolution:
:
:
::10mA
Band wide up to 200KHz(-3dB)
Error by earth magnetic: ± 30mA max
Remanence(±100A
0A):
:
:
:: ± 30mA max
Jaw size: 23mm (Max)
Auto Zero at power on
Low battery/return to zero indicator: When the battery voltage is lower
than the operating voltage, the indicator lights up; When press
the return to zero key, the output automatically return to zero, at
the same time the indicator light on, after the end of the return to
zero yellow and green indicator light automatically out.
Power Supply: 9V 6F22 Battery
Power Consumption:280mW (typical)
Operating temperature and humidity:
0C to 40C ,relative humidity below 70%RH
Store temperature and humidity:
-10C to 60C ,relative humidity below 70%RH
Size: 180mm(L)x 44mm(W)x 30mm(H)
Weight: Approx. 200g
Accessories: Manual,Battery
3.2ELECTRICAL SPECIFICATIONS
Accuracy are (%rdg + Number of current) at 23C5C below 70%RH;
DC CURRENT:
Range
Accuracy
Sensitivity
4A
±1.5%rdg±5d
1 mV/10 m A
40A
±1.5%rdg±5d
1 mV/ 0.1A
300A
±1.5%rdg±5d
1 mV/ 1A
300A~400A
±3.5%rdg±5d
1 mV/ 1A
AC CURRENT:

Range
Accuracy
Sensitivity
4A
±2.0%rdg±5d
1 mV/10mA
40A
±2.0%rdg±5d
1 mV/0.1A
300A
±2.0%rdg±5d
1 mV/ 1A
300A~400A
±3.5%rdg±5d
1 mV/ 1A
4、
、
、
、、Panel Description
1. Probe jaw
2. Tong head machine
3. Gear switch
4. Power indicator
5. ZERO Key
6. Indicator panel
7. Output socket
8. Low battery/return to zero indicator
Figure 1
5、
、
、
、、Operating Instruction
5.1 DC current measurement
5.1.1 Choose the right gear 4A,40A or 400A.
( : )Note Turn on and wait about 5 seconds.
5.1.2 Connect the clamp current probe and an apparatus (Fig. 2).
5.1.3 Make sure that the connection wire of the pliers meter is securely
connected to the input end of the oscilloscope.
5.1.4 Before measuring, please press the ZERO back to Zero button until the
oscilloscope read value is zero.
(
(
(
((Note:
:
:
::It is normal to read 0~ 1.0mV after pressing the back to zero
button in DC 4A gear.)
)
)
))
5.1.5 Press the board machine to open the clamp and clamp a wire to be
tested.Confirm that there is no gap between movable and fixed.
5.1.6 Read the current value on LCD.
5.2 AC current measurement
5.2.1 Choose the right gear 4A,40A or 400A.
( : )Note Turn on and wait about 5 seconds.
5.2.2 Connect the clamp current probe and an apparatus (Fig. 2).
5.2.3 Make sure that the connection wire of the pliers meter is securely
connected to the input end of the oscilloscope.
5.2.4 Press the board machine to open the clamp and clamp a wire to be
Product Specifications
Brand: | Owon |
Category: | Measuring equipment |
Model: | CP024 |
Do you need help?
If you need help with Owon CP024, ask a question below and other users will answer you
Measuring equipment Owon User Manuals

23 October 2024

22 October 2024

22 October 2024

21 October 2024

20 October 2024

19 October 2024

13 October 2024

13 October 2024
Measuring equipment User Manuals
- Measuring equipment EBERLE
- Measuring equipment Hazet
- Measuring equipment Fluke
- Measuring equipment Megger
- Measuring equipment Kogan
- Measuring equipment AkYtec
- Measuring equipment Voltcraft
- Measuring equipment Klein Tools
- Measuring equipment PeakTech
- Measuring equipment Clean Air Optima
- Measuring equipment Flex
- Measuring equipment CSL
- Measuring equipment Elgato
- Measuring equipment Kern
- Measuring equipment Be Cool
- Measuring equipment ORNO
- Measuring equipment Einhell
- Measuring equipment Mitsubishi
- Measuring equipment Noyafa
- Measuring equipment Megasat
- Measuring equipment Reely
- Measuring equipment Joy-it
- Measuring equipment Logilink
- Measuring equipment Basetech
- Measuring equipment Gossen Metrawatt
- Measuring equipment TFA
- Measuring equipment Extech
- Measuring equipment Milesight
- Measuring equipment Sonel
- Measuring equipment Flir
- Measuring equipment Testo
- Measuring equipment MSW
- Measuring equipment Stamos
- Measuring equipment Ideal
- Measuring equipment Hikmicro
- Measuring equipment Siglent
- Measuring equipment Kopp
- Measuring equipment PICO
- Measuring equipment Enda
- Measuring equipment Wachendorff
- Measuring equipment Ermenrich
- Measuring equipment Beha-Amprobe
- Measuring equipment Adwa
- Measuring equipment Tempo
- Measuring equipment PCE Instruments
- Measuring equipment Vemer
- Measuring equipment Testboy
- Measuring equipment Duro Pro
- Measuring equipment Kyoritsu
- Measuring equipment Benning
- Measuring equipment MASIMO
- Measuring equipment Stahlwille
- Measuring equipment SHX
Latest Measuring equipment User Manuals

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024