Building Electronic Thermometer
02
NF 514-
VER: V1
User Manual
ๅปบ็ญ็ตโผฆๆตๆธฉไปช
36.8
Switch Backlight
Lighting
Temperature range
Measurement Error
Environment Temperature
Shenzhen Noyafa Electronic Co., Ltd
1ใOverview
The๎ instrument๎ is๎ Portable๎ Building๎ Elect ronic๎ Thermometer๎ is๎ a๎
pr of es si on a l๎ tem pe r at u re๎ mea s ur i n g๎ in str u me nt ๎ de v el op ed๎
accordin g๎ to๎ the๎ con struction๎ characterist ics๎ of๎ my ๎ country's๎
construction๎ industry๎ and๎ relevant๎ technical๎ speci๏ฌcations.๎ It๎ can๎
display๎the๎measured๎temperature๎intuitively,๎accurately๎and๎quickly,๎
with๎ good๎ reliability,๎ wide๎ range๎ of๎ use๎ and๎ applications.๎ Warm๎
operating๎ environment,๎ small๎ size๎ and๎ light๎ weight,๎ easy๎ to๎ carry,๎
suitable๎ for๎ constr ucti on๎ sites๎ and๎ ๏ฌeld๎ operations;๎ mainly๎ used๎ fo r๎
const ructi on,๎ bui lding๎ materials,๎w ater๎ conservancy,๎ electric๎p ower,๎
metallurgy,๎ pe trochemical,๎ po rts,๎ ro ads๎ an d๎ bridges,๎ municipal๎ and๎
other๎basic๎const ruction๎projects.
2ใ๎Scope๎Of๎Application
The๎ instrument๎ is๎ suitable๎ for๎ on-site๎ construction๎ temperature๎
measurement๎ of๎ various๎ construction๎ projects.๎ It๎ can๎ be๎ used๎ with๎
temperature๎ measurement๎ probes๎ to๎ measure๎ the๎ temperature๎ of๎
materials๎and๎clinker,๎such๎as:๎gas,๎liquid,๎๏ฌuid,๎mixture๎and๎granular๎
materials;๎ a nd๎ embedded๎ te mperature๎ me asurement๎ line.๎ I t๎ can๎ be๎
used๎ to๎ measure๎ the๎ internal๎ temperature๎ of๎ winter๎ construction๎
concrete๎and๎mass๎concrete.
3ใ๎The๎composition๎and๎function๎of๎the๎instrument
ๅปบ็ญ็ตโผฆๆตๆธฉไปช
NF 514-
36.8
Switch Backlight
Lighting
Temperat ure range
M easurem ent E rror
Envir onment Te mperatu re
Shen zhe n No yafa El ectro nic Co., Ltd
LCD
Power Switch
Power Switch
Backlight Switch
Temperature Probe
Temperature๎probe
The๎temperature๎measuring๎probe๎is๎made๎of๎a๎plug,๎a๎wire,๎a๎handle๎
and๎ a๎ metal๎ tube๎ with๎ an๎ outer๎ diameter๎ of๎ 5mmร220mm.๎ The๎ฮฆ
front๎end๎of๎the๎tube๎is๎packaged๎with๎a๎temperature๎sensor,๎which๎is๎
suitable๎for๎measuring๎the๎temperature๎of๎materials๎and๎clinker.
2
Main๎Tester
The๎ instrument๎ is๎ suitable๎ for๎ on-site๎ construction๎ temperature๎
measurement๎ o f๎ var ious๎ co nstruction๎ projects.๎ It๎ can๎ b e๎ used๎ with๎
temperature๎ measurement๎ probes๎ to๎ measure๎ the๎ temperature๎ of๎
materials๎and๎clinker,๎such๎as:๎gas,๎liquid,๎๏ฌuid,๎mixture๎and๎granular๎
materials;๎ and๎ embedd ed๎ tempe rature๎measurement๎ line.๎ I t๎ can๎ be๎
used๎ to๎ measure๎ the๎ internal๎ temperature๎ of๎ winter๎ construction๎
concrete๎and๎mass๎concrete.
1
Tem perature๎measurement๎line
3
The๎embedded๎temperature๎measuring๎line๎is๎made๎of๎a๎plug,๎a๎wire๎
and๎ a๎ temperature๎ sensor,๎ which๎ is๎ suitable๎ for๎ measuring๎ the๎
internal๎ temperature๎ of๎ t he๎ concrete.๎ Each๎ temperature๎ m easu rin g๎
line๎can๎measure๎the๎temperature๎at๎one๎point,๎and๎t he๎temperature๎
measuring๎point๎can๎be๎arranged๎arbitrarily๎during๎the๎construction.๎
In๎ o rder๎ to๎ fa cilitate๎ layered๎ te mpe rature๎measurement,๎the๎ plug๎of๎
each๎ temperature๎ measurement๎ cable๎ has๎ a๎ label๎ a๏ฌxed๎ with๎ a๎
corresponding๎lengt h๎speci๏ฌcation.
4ใ๎The๎main๎technical๎indicators
Temperature๎measurement๎range:๎-30ยฐC~150ยฐC
Temperature๎measurement๎error:๎โคยฑ0.5ยฐC
Operating๎environment๎temperature:๎20ยฐC~50ยฐโ
Display๎mode:๎3-digit๎LCD๎screen
Power๎supply:๎9V๎laminated๎battery
Weight:๎200g
Host๎volume:๎135mmร72mmร32mm
Resolution:๎0.1ยฐC
1
2
3
4
5
6
7
8
5ใ๎Use๎method
Use๎the๎host๎and๎temperature๎probe๎to๎measure๎the๎temperature๎
of๎the๎material
1
Insert๎the๎plug๎of๎the๎temperature๎probe๎into๎the๎socket๎of๎the๎host,๎
press๎the๎power๎switch,๎and๎insert๎the๎metal๎claw๎of๎the๎temperature๎
probe๎into๎the๎object๎to๎be๎measured,๎the๎insertion๎depth๎is๎not๎less๎
than๎1/2๎of๎its๎length,๎and๎the๎temperature๎data๎is๎read๎on๎the๎host๎in๎
about๎two๎minutes.๎When๎measuring๎the๎temperature๎of๎the๎mixt ure,๎
in๎ order๎ to๎ a void๎ ex cessive๎ impact๎ betw een๎ the๎ t empe rature๎ probe๎
and๎the๎hard๎objects๎in๎the๎mixture๎and๎a๏ฌect๎the๎service๎life,๎a๎metal๎
rod๎ can๎ be๎ used๎ to๎ reserve๎ a๎ hole๎ in๎ the๎ mixture,๎ and๎ then๎ the๎
temperature๎ probe๎ can๎ be๎ inserted๎ into๎ the๎ hole๎ Temperature๎
measurement.๎ Th e๎ tempe rature๎ probe๎ should๎ be๎ wiped๎ cle an๎ aft er๎
each๎use.
Measure๎the๎temperature๎o f๎mass๎concrete๎with๎the๎host๎and๎
temperature๎measuring๎line
2
After the construc ti on te m pe rature measurement pl an is determined,
select a tempera ture meas u rement lin e with appropri ate leng th
speci๏ฌcations according to the number and d ep th o f the temperature
m ea s u r e m e nt p o i n t s , f o r e xa m p l e : t h e a ct u a l t e m p e r a t u r e
01 03
06
6ใ๎Battery๎replacement
1
measurement point depth is 0.2m~0.3m, and the 0.5m temperature
m e a s u r e m e n t l i n e c a n b e s e l e c t e d ; th e a c t u a l t e m p e r a t u r e
measurement The point depth is 2.5m~2.8m, and the temperature
measurement line with a speci๏ฌcation of 3m can be selected, and so
on. When pre-embedded, steel bars and other pieces can be used as
supports, and the temperature measurement line is tied to the support
according to the distance of the longitudinal temperature measurement
point. The temperature sensor and the support should be insulated.
When pouring the concrete, implant the support with the temperature
measuring wire into the concrete, the temperature sensor is at the
temperature measuring point, and the plug is left outside of the
concrete and covered with a plastic bag to avoid moisture and keep it
clean. For ease of operation, the length of the wire left outside should
be greater than 20cm. When measuring the temperature, press the
power switch of the main unit and insert the plug of the temperature
measurement line into the socket of the main unit, and the temperature
of the corresponding temperature measurement point can be displayed
on the main unit's display screen.
When๎ pouring๎ concrete,๎ reserve๎ temperature๎ measurement๎ holes๎
according๎ to๎ the๎ winter๎ construction๎ temperature๎ measurement๎
plan,๎place๎a๎temperature๎measurement๎wire๎in๎each๎hole,๎and๎leave๎
the๎plug๎of๎ the๎temperature๎measurement๎wire๎outside๎the๎ hole๎and๎
cover๎it๎with๎a๎plastic๎ bag๎to๎avoid๎ moisture๎and๎keep๎it๎ clean.๎When๎
measuring๎the๎ temperature,๎press๎the๎power๎switch๎of๎the๎main๎unit๎
and๎ insert๎ the๎ plug๎ of๎ the๎ temperature๎ measurement๎ line๎ into๎ the๎
socket๎ of๎ the๎ main๎ unit,๎ and๎ the๎ temperature๎ of๎ the๎corresponding๎
temperature๎measurement๎point๎can๎be๎displayed๎on๎the๎main๎unit's๎
display๎ screen.๎ After๎ each๎ stage๎ of๎ temperature๎ measurement,๎ the๎
temperature๎ measurement๎ line๎ will๎ be๎ stored๎ for๎ future๎ use.๎ The๎
temperature๎ measuring๎ line๎ can๎ also๎ be๎ buried๎ in๎ the๎ concrete๎ for๎
one-time๎use.
Use๎the๎host๎and๎temperature๎measuring๎line๎to๎measure๎the๎concrete๎
๎temperature๎during๎winter๎construction
3
Use๎of๎night๎temperature๎reading๎and๎lighting๎function
4
When๎used๎at๎night๎or๎in๎a๎dark๎environment,๎press๎the๎host๎backlight๎
switch,๎ the๎ LCD๎ screen๎ can๎emit๎ blue๎ background๎ light,๎ making๎ the๎
reading๎clear๎and๎eye-catching.๎Press๎the๎light๎switch,๎the๎light๎turns๎
on,๎which๎is๎equivalent๎to๎a๎๏ฌashlight.
When๎LOBAT๎appears๎in๎the๎upper๎left๎corner๎of๎the๎display๎of๎the๎host๎
or๎ cannot๎ be๎ turned๎ on๎ normally,๎ it๎ is๎ usually๎caused๎ by๎ insu๏ฌcient๎
battery๎voltage,๎and๎a๎new๎batter y๎needs๎to๎be๎replaced.๎The๎method๎
is๎ as๎ follows:๎Open๎the๎ battery๎compartment๎ cover๎behind๎ the๎ main๎
unit,๎take๎out๎the๎old๎battery๎from๎ the๎ battery๎compartment,๎ buckle๎
the๎ new๎ batter y,๎and๎then๎restore๎ the๎ battery๎compartment๎cover๎ to๎
its๎original๎position.
7ใ๎Battery๎replacement
When๎ the๎ host๎ is๎ not๎ connected๎ to๎ the๎ temperature๎ measuring๎
probe๎ or๎ the๎ temperature๎measuring๎line,๎ "-1"๎is๎displayed๎on๎the๎
display๎as๎the๎preparation๎state.
2Do๎ not๎use๎excessive๎ force๎during๎ operation.๎ Hold๎the๎ plug๎ ๏ฌrmly๎
when๎inserting๎or๎unplugging๎the๎plug๎into๎ or๎out๎of๎ the๎ socket๎of๎
the๎host.
3If๎the๎plug๎or๎the๎socket๎of๎the๎main๎unit๎gets๎wet๎due๎to๎accidental๎
ingress๎of๎ water,๎please๎ wipe๎ it๎ and๎dry๎ it๎before๎using๎ it๎to๎ avoid๎
inaccurate๎temperature๎measurement๎results.
4The๎ instrument๎ should๎ be๎ turned๎ o๏ฌ๎ in๎ time๎ after๎ use,๎ and๎ the๎
battery๎should๎ be๎ removed๎ when๎it๎ is๎not๎used๎for๎ a๎ long๎ time๎to๎
avoid๎damage๎to๎the๎instrument.
5Do๎ not๎ open๎ the๎ back๎ cover๎of๎ the๎ main๎unit๎ by๎ yourself.๎ Please๎
send๎ it๎ back๎ to๎ the๎ manufacturer๎ or๎ agency๎ when๎ you๎ need๎ to๎
repair๎or๎calibrate๎it.
8ใ๎Accessories
11๎copy๎of๎instruction๎manual
21๎copy๎of๎product๎inspection๎certi๏ฌcate
31๎copy๎of๎product๎warranty๎card
4Instrument๎sets๎1๎piece
5Batteries
9ใ๎Options
0.5mใ1mใ1.5mใ 2 mใ 2.5mใ3mใ
3.5mใ4mใ4.5mใ 5 m
01
02
03
Optional๎๎๎accessories
Temperature๎probe
Optional๎speci๏ฌcation๎of๎temperature๎
measuring๎line.
Other๎speci๏ฌcations๎of๎the๎temperature๎
measuring๎line๎can๎be๎customized.
0504 07
ๅปบ็ญ็ตโผฆๆตๆธฉไปช
36.8
Switch Backlight
Lighting
Temperature range
Measurement Error
Environment Temperature
Shenzhen Noyafa Electronic Co., Ltd
Building Electronic Thermometer
Product Specifications
Brand: | Noyafa |
Category: | Measuring equipment |
Model: | NF-514 |
Do you need help?
If you need help with Noyafa NF-514, ask a question below and other users will answer you
Measuring equipment Noyafa User Manuals
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
Measuring equipment User Manuals
- Measuring equipment EBERLE
- Measuring equipment Hazet
- Measuring equipment Fluke
- Measuring equipment Megger
- Measuring equipment Kogan
- Measuring equipment AkYtec
- Measuring equipment Voltcraft
- Measuring equipment Klein Tools
- Measuring equipment PeakTech
- Measuring equipment Clean Air Optima
- Measuring equipment Flex
- Measuring equipment CSL
- Measuring equipment Elgato
- Measuring equipment Kern
- Measuring equipment Be Cool
- Measuring equipment ORNO
- Measuring equipment Einhell
- Measuring equipment Mitsubishi
- Measuring equipment Megasat
- Measuring equipment Reely
- Measuring equipment Joy-it
- Measuring equipment Logilink
- Measuring equipment Basetech
- Measuring equipment Gossen Metrawatt
- Measuring equipment TFA
- Measuring equipment Owon
- Measuring equipment Extech
- Measuring equipment Milesight
- Measuring equipment Sonel
- Measuring equipment Flir
- Measuring equipment Testo
- Measuring equipment MSW
- Measuring equipment Stamos
- Measuring equipment Ideal
- Measuring equipment Hikmicro
- Measuring equipment Siglent
- Measuring equipment Kopp
- Measuring equipment PICO
- Measuring equipment Enda
- Measuring equipment Wachendorff
- Measuring equipment Ermenrich
- Measuring equipment Beha-Amprobe
- Measuring equipment Adwa
- Measuring equipment Tempo
- Measuring equipment PCE Instruments
- Measuring equipment Vemer
- Measuring equipment Testboy
- Measuring equipment Duro Pro
- Measuring equipment Kyoritsu
- Measuring equipment Benning
- Measuring equipment MASIMO
- Measuring equipment Stahlwille
- Measuring equipment SHX
Latest Measuring equipment User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024