INSTRUCTION MANUAL
Dual-Range High-Voltage
Non-Contact Tester
Low Range: 50V to 1.5kV AC
High Range: 1.5kV to 132kV AC
Français pg. 25
Español pg. 13
ENGLISH
HVNCVT1
2
SYMBOLS
Warning or Caution
Risk of Electrical Shock
Double Insulated
GENERAL SPECIFICATIONS
The Dual-Range High-Voltage Non-Contact Tester (HVNCVT1) checks for the
presence of AC voltage without making any disconnection in cables, wall sockets,
fuses, circuit breakers, junction boxes, etc. No current flow is needed for correct
operation. The tester warns against dangerous voltage from low to high voltage
applications up to 132kV without contacting the energized conductor. The low-
range setting should be used for detecting 50V AC to 1.5kV AC. It may be used as
a hand-held device ONLY when checking for low voltage. The high-range setting
should be used for detecting 1.5kV AC to 132kV AC. It should ONLY be used with a
hot stick when checking for high voltage.
Always follow approved work safety practices and clearances per OSHA Sub-parts
R & V and all company work rules. For Minimum Approach Distances (MAD), see
OSHA Tables R-6 and R-7 (pages 8 & 9) in this manual.
• Operating Temperature: 32° to 122°F (0° to 50°C) @ 85% relative humidity
• Storage Temperature: 14° to 122°F (-10° to 50°C) @ 85% relative humidity
• Dimensions: Tester: 13" x 3.15" x 2.64" (330 x 80 x 67mm)
Case: 14" x 8" x 3.5" (356 x 203 x 89 mm)
• Weight: 8 oz. (227 g)
• Power Source: One 9V battery
• Power Consumption:
Off:
Less than 5uA
Low range mode:
(50V to 1.5kV AC) Less than 40mA
High range mode:
(1.5kV to 132kV AC) Less than 40mA
Specifications subject to change.
ENGLISH
3
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Use extreme caution when testing live electrical circuits due to risk of injury from
electrical shock.
• When testing for high voltage, always use hot sticks and rubber gloves meeting
industry standards.
• Follow approved work safety practices and clearances per OSHA Sub-parts
R & V and your company work rules.
• Always test on a known live circuit to verify tester functionality prior to use.
• Do not exceed the limits marked on the instrument itself. Never test voltage
more than 132kV AC RMS.
• Never ground yourself when taking measurements. Do not touch exposed
circuit elements.
• Observe the proper safety precautions when working with voltage above 30V AC
RMS to avoid electrical shock hazard.
• Do not assume equipment or conductors are, or will remain, de-energized.
Always install proper grounding devices before starting procedure.
• Do not operate tester in an explosive atmosphere.
• Do not expose tester to rain or moisture. This increases the risk of fire
or electric shock.
• Do not rely on this tester for shielded wire or cable with concentric neutrals.
• Do not let the unit make contact with live line voltage. Do not touch any exposed
wiring, connections or other energized parts of an electrical circuit.
• 3-phase feeder cables with conductors close to each other may self-cancel the
electric field and not be detected by the device. Verify that the phase conductors
are separated by at least 15" (381 mm) before testing for AC voltage.
Product Specifications
Brand: | Klein Tools |
Category: | Measuring equipment |
Model: | HVNCVT-1 |
Do you need help?
If you need help with Klein Tools HVNCVT-1, ask a question below and other users will answer you
Measuring equipment Klein Tools User Manuals
27 October 2024
27 October 2024
27 October 2024
17 October 2024
15 October 2024
15 October 2024
15 October 2024
15 October 2024
15 October 2024
13 October 2024
Measuring equipment User Manuals
- Measuring equipment EBERLE
- Measuring equipment Hazet
- Measuring equipment Fluke
- Measuring equipment Megger
- Measuring equipment Kogan
- Measuring equipment AkYtec
- Measuring equipment Voltcraft
- Measuring equipment PeakTech
- Measuring equipment Clean Air Optima
- Measuring equipment Flex
- Measuring equipment CSL
- Measuring equipment Elgato
- Measuring equipment Kern
- Measuring equipment Be Cool
- Measuring equipment ORNO
- Measuring equipment Einhell
- Measuring equipment Mitsubishi
- Measuring equipment Noyafa
- Measuring equipment Megasat
- Measuring equipment Reely
- Measuring equipment Joy-it
- Measuring equipment Logilink
- Measuring equipment Basetech
- Measuring equipment Gossen Metrawatt
- Measuring equipment TFA
- Measuring equipment Owon
- Measuring equipment Extech
- Measuring equipment Milesight
- Measuring equipment Sonel
- Measuring equipment Flir
- Measuring equipment Testo
- Measuring equipment MSW
- Measuring equipment Stamos
- Measuring equipment Ideal
- Measuring equipment Hikmicro
- Measuring equipment Siglent
- Measuring equipment Kopp
- Measuring equipment PICO
- Measuring equipment Enda
- Measuring equipment Wachendorff
- Measuring equipment Ermenrich
- Measuring equipment Beha-Amprobe
- Measuring equipment Adwa
- Measuring equipment Tempo
- Measuring equipment PCE Instruments
- Measuring equipment Vemer
- Measuring equipment Testboy
- Measuring equipment Duro Pro
- Measuring equipment Kyoritsu
- Measuring equipment Benning
- Measuring equipment MASIMO
- Measuring equipment Stahlwille
- Measuring equipment SHX
Latest Measuring equipment User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024