Model 412300A Current Calibrator
412300A-EU-EN v3.4 07/13 2
1
2
3
4
5
6
6
7
Introduction
Congratulations on your purchase of the Extech Current Calibrator Model 412300A. The 412300A
can measure/source current and can also power a current loop. A built-in five location memory
can store customized calibration current output steps. The Oyster Series meters have a
convenient flip up display with neck-strap for hands-free operation. This meter is shipped fully
tested and calibrated and, with proper use, will provide years of reliable service.
Meter Description
1. LCD display
2. Battery Compartment
3. AC adaptor jack
4. Calibration Cable input
5. Function switch
6. Neck-strap posts
7. Keypad
412300A-EU-EN v3.4 07/13 3
Keypad and Switch Descriptions
POWER BUTTON and AUTO POWER OFF FEATURE
1. Use the POWER button to turn the unit ON or OFF. When the unit is powered up, a short self-
test will ensue after which the display will stabilize.
2. This meter can either be powered by one 9V battery or an AC adapter.
3. When the battery symbol appears on the LCD display, replace the battery as soon as possible.
Low battery power may cause inaccurate readings and erratic meter operation.
4. This instrument is equipped with Auto Power OFF which turns the meter off after 10 minutes of
inactivity. To override this feature; press and hold the MODE button until the display shows
(auto power off de-activated) or (auto power off activated).
FUNCTION SLIDE SWITCH
1. Slide the Function switch on the side of the meter to the desired function (Source/Measure or
Power/Measure).
2. In the Source/Measure position the meter can be used to generate current or measure current
(MODE button is used to choose Source or Measure).
3. In the Power/Measure position, the meter can power a current loop with 24Vdc and, at the same
time, measure the current.
MODE BUTTON
Press the MODE button to select either SOURCE (output) or MEASURE (input). This applies when
the Function switch is set to Source/Measure.
UNIT BUTTON
Press the UNIT button to select mA or % units.
▲▼ INCREASE / DECREASE BUTTONS
Use the â–² â–¼ buttons to increase or decrease the output current value in the source mode.
1. Press the â–² button once to increase the value in one digit steps.
2. Press and hold the
â–² button to increase the value in 10 digit steps.
3. Press and hold the
â–² â–¼ button >2 sec and then press the to increase the value in 100 digit
steps
4. To decrease the value, use the
â–¼ button as described above.
ZERO BUTTON
The ZERO button manually zeros the display in the MEASURE mode.
1. Set the meter to the MEASURE mode
2. Short the input jack
3. Press and release the ZERO button
Product Specifications
Brand: | Extech |
Category: | Measuring equipment |
Model: | 412300A |
Do you need help?
If you need help with Extech 412300A, ask a question below and other users will answer you
Measuring equipment Extech User Manuals
26 October 2024
22 October 2024
22 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
Measuring equipment User Manuals
- Measuring equipment EBERLE
- Measuring equipment Hazet
- Measuring equipment Fluke
- Measuring equipment Megger
- Measuring equipment Kogan
- Measuring equipment AkYtec
- Measuring equipment Voltcraft
- Measuring equipment Klein Tools
- Measuring equipment PeakTech
- Measuring equipment Clean Air Optima
- Measuring equipment Flex
- Measuring equipment CSL
- Measuring equipment Elgato
- Measuring equipment Kern
- Measuring equipment Be Cool
- Measuring equipment ORNO
- Measuring equipment Einhell
- Measuring equipment Mitsubishi
- Measuring equipment Noyafa
- Measuring equipment Megasat
- Measuring equipment Reely
- Measuring equipment Joy-it
- Measuring equipment Logilink
- Measuring equipment Basetech
- Measuring equipment Gossen Metrawatt
- Measuring equipment TFA
- Measuring equipment Owon
- Measuring equipment Milesight
- Measuring equipment Sonel
- Measuring equipment Flir
- Measuring equipment Testo
- Measuring equipment MSW
- Measuring equipment Stamos
- Measuring equipment Ideal
- Measuring equipment Hikmicro
- Measuring equipment Siglent
- Measuring equipment Kopp
- Measuring equipment PICO
- Measuring equipment Enda
- Measuring equipment Wachendorff
- Measuring equipment Ermenrich
- Measuring equipment Beha-Amprobe
- Measuring equipment Adwa
- Measuring equipment Tempo
- Measuring equipment PCE Instruments
- Measuring equipment Vemer
- Measuring equipment Testboy
- Measuring equipment Duro Pro
- Measuring equipment Kyoritsu
- Measuring equipment Benning
- Measuring equipment MASIMO
- Measuring equipment Stahlwille
- Measuring equipment SHX
Latest Measuring equipment User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024