Festo SDBT-BSW-1L-PU-W-5-N-LE Manual

Festo Not categorized SDBT-BSW-1L-PU-W-5-N-LE

Read below 📖 the manual in Italian for Festo SDBT-BSW-1L-PU-W-5-N-LE (1 pages) in the Not categorized category. This guide has been helpful for 8 people and has been rated 4.5 stars on average by 2 users

Page 1/1
Translation of the original instructions
© 2020 all rights reserved to Festo SE & Co. KG
1 Applicable Documents
All available documents for the product www.festo.com/sp.è
2 Safety
2.1 Safety
– Before working on the electrics: switch off the voltage supply.
WARNING!
Risk of injury due to electric shock.
• For the electric power supply, use only PELV circuits that ensure a reliable
electric disconnection from the mains network.
• Observe IEC60204-1/EN60204-1.
2.2 Intended use
This product is intended for sensing the position of magnets (e.g. the piston posi-
tion) in Festo products. The device is intended for use in an industrial environ-
ment.
2.2.1 Area of application and approval
In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.
UL approval information
Product category code NRKH, NRKH7
File number E232949
Considered standards UL 60947-1, CAN/CSA C22.2 No. 60947-1
UL 60947-5-2, CAN/CSA C22.2 No. 60947-5-2
UL mark
Industrial Control Equipment
2MD1
Tab. 1
Only for connection to a NEC/CEC Class 2 supply.
3 Electrical connection
Circuit diagrams
SDBT-BSW-…-PU-…-M12 SDBT-BSW-…-PU-…-LE
SDBT-BSW-…-NU-…-M12 SDBT-BSW-…-NU-…-LE
SDBT-BSW-…-ZU-…-LE
Tab. 2
4 Mechanical installation
Fig. 1 Mechanical installation
5 Operating conditions
If the SDBT-BSW-...-PU or SDBT-BSW-...-NU is aligned at a right angle to the weld-
ing electrode or cable, it can result in maloperations in a limited range (applica-
tion-dependent).
Fig. 2 Operating conditions
Possible remedy:
– Adjust the distance between the proximity sensor and the source of malfunc-
tion (±20mm).
– Adjust the angle between the proximity sensor and the source of malfunction
(±20°).
– Adjust the strength of the welding current.
– On DW/DWA/DWB cylinders: mount sensor in a different position.
6 Technical data
6.1 Technical data UL
SDBT-BSW-…
Operating voltage range [VDC] 10…30
Ambient temperature [°C] –25…+80
NEMA enclosure type number
(Enclosure Type Rating)
Type 1
Tab. 3
6.2 Technical data, general
SDBT-BSW- - PU/NU ZU…
Operating voltage range [VDC] 10…30
Max. output current [mA] 100 80
Max. switching capacity [W] 2.8 1.9
Frequency of welding process
MFDC
[Hz] 1000 –
Frequency of welding process
AC
[Hz] 50…60
Ambient temperature [°C] –25…+85
Ambient temperature with flex-
ible cable installation
[°C] –5…+80
Degree of protection IP65, IP68
Tab. 4
8140618
SDBT-BSW-...
Proximity sensor
8140618
2020-07c
[8140620]
Operating instructions
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com

Product Specifications

Brand: Festo
Category: Not categorized
Model: SDBT-BSW-1L-PU-W-5-N-LE

Do you need help?

If you need help with Festo SDBT-BSW-1L-PU-W-5-N-LE, ask a question below and other users will answer you




Not categorized Festo User Manuals

Not categorized User Manuals

Latest Not categorized User Manuals