Radson 51052 - SLAVE RF 4 or 6 Zones Thermostaat Manual

Radson Thermostat 51052 - SLAVE RF 4 or 6 Zones Thermostaat

Read below 📖 the manual in Italian for Radson 51052 - SLAVE RF 4 or 6 Zones Thermostaat (28 pages) in the Thermostat category. This guide has been helpful for 3 people and has been rated 4.5 stars on average by 2 users

Page 1/28
USER GUIDE GB
UFH MASTER RF 6 Zones & SLAVE RF 4 or 6 Zones 3-6
GUIDE UTILISATEUR F
UFH MASTER RF 6 Zones & SLAVE RF 4 or 6 Zones 7-10
MONTAGE ANLEITUNG D
FUNK- SCHALTLEISTE MASTER 6 KANÄLE 11-14
HANDLEIDING Nl
UFH MASTER RF 6 Zones & UITBREIDING 4 of 6 Zones 15-18
INSTRUKCJA UŻYTKOWANIA Pl
UFH Listwa MASTER RF 6 Stref 19-22
MANUALUL UTILIZATORULUI Ro
UFH MASTER RF 6 Zone & SLAVE RF 4 sau 6 Zone 23-26
UFH MASTER RF 6 Zones
& SLAVE RF 4 or 6 Zones
2
3
1. USER GUIDE
UFH MASTER RF 6 Zones & SLAVE RF 4 or 6 Zones
Wireless (RF 868MHz) connecting boxes specially designed to control your Under Floor Heating managed by
Normally Closed actuators.
Possibility to extend easily the number of zones up to 12, with the slave modules.
Work in combination with our UFH-RF thermostat range (Digital and Basic)
2. TECHNICAL CHARACTERISTICS
Operating Temperature
0°C to 50°C
Regulation characteristics
Proportional Integral regulation with: 15 minutes cycle for 2°C.
Anti-short cycle: 3 minutes OFF, 2 minutes ON
Supply Voltage
230VAC +- 10% 50Hz
Outputs:
Pump or accessories
Actuators (Normally closed)
Relay => 5A / 250VAC (Free contact)
Relay => 5A / 230 VAC ( L, N)
For easy installation we recommend a maximum of 4 actuators by
zones.
Radio Frequency
868, 3 MHz, <10mW.
Range of approximately 180 meters in open space.
Range of approximately 50 meters in residential environment.
Certifications
EN 300220-1, -2
EN 301489-1, -3
Protection
IP 30
Combination
10 Zones => 1 Master 6 + 1 Slave 4 zones
12 Zones => 1 Master 6 + 1 Slave 6 zones
3. LED EXPLANATION
In normal working mode:
Green Flash:
RF signal reception from the thermostat assigned on this zone.
Red:
Heating demand indicator (Water circulation on this zone)
Red Blinking:
RF alarm, the communication between thermostat and the Master has been lost.
Check the thermostat batteries. (When batteries thermostat must be changed, always replace the 2 batteries)
* If all zones are Red blinking check the RF antenna connection before replacing of all thermostat batteries.
4. POSSIBLE COMBINATIONS WITH SLAVE MODULES
5.

Product Specifications

Brand: Radson
Category: Thermostat
Model: 51052 - SLAVE RF 4 or 6 Zones Thermostaat

Do you need help?

If you need help with Radson 51052 - SLAVE RF 4 or 6 Zones Thermostaat, ask a question below and other users will answer you




Thermostat Radson User Manuals

Thermostat User Manuals

Latest Thermostat User Manuals

Heatmiser

Heatmiser PRT-ETS Manual

25 October 2024
Heatmiser

Heatmiser PRT-W Manual

25 October 2024
Heatmiser

Heatmiser PRTHW Manual

25 October 2024
Heatmiser

Heatmiser PRT-EWTS Manual

25 October 2024
Heatmiser

Heatmiser DT-N Manual

25 October 2024
Heatmiser

Heatmiser DT-EW Manual

25 October 2024
Heatmiser

Heatmiser PRTHW-WTS Manual

25 October 2024
Heatmiser

Heatmiser PRT-RPTS Manual

25 October 2024
Heatmiser

Heatmiser PRT-RP Manual

25 October 2024
Heatmiser

Heatmiser PRT-B Manual

25 October 2024