INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Wall Heaters
9810WH, 9815WH SERIES
READ ALL INSTRUCTIONS BEFORE INSTALLING OR
USING THIS HEATER.
To reduce the risk of fire, electric shock, or injury to persons,
observe the following:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number listed
in the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
5. This heater is hot when in use. To avoid burns, do not
let bare skin touch hot surfaces. Keep combustible
materials, such as furniture, pillows, bedding, papers,
clothes, etc. and curtains at least 3 feet (0.9 m) from the
front of the heater.
6. Extreme caution is necessary when any heater is used
by or near children or invalids and whenever the heater
is left operating and unattended.
7. Do not operate any heater after it malfunctions.
Disconnect power at service panel and have heater
inspected by a reputable electrician before reusing.
8. Do not use outdoors.
9. To disconnect heater, turn controls to off, and turn off
power to heater circuit at main disconnect panel (or
operate internal disconnect switch, if provided).
10. Do not insert or allow foreign objects to enter any
ventilation or exhaust opening, as this may cause an
electric shock or fire, or damage the heater.
11. To prevent a possible fire, do not block air intakes or
exhaust in any manner.
12. A heater has hot and arcing or sparking parts inside. Do
not use it in areas where gasoline, paint, or flammable
vapors or liquids are used or stored.
13. Use this heater only as described in this manual. Any
other use not recommended by the manufacturer may
cause fire, electric shock, or injury to persons.
14. Install heater at least 6 inches from floor or any adjacent
wall.
15. To avoid electrical shock: Do not install unit in a tub or
shower enclosure or any location where it may come in
contact with water. Never place a switch where it can be
reached from a tub or shower.
16. This product may ONLY be installed vertically in a wall.
Do not mount in any other position.
17. Do not connect heater to dimmer switch or speed control.
18. This product must be grounded.
SAVE THESE INSTRUCTIONS
IMPORTANT INSTRUCTIONS
SAFETY INSTRUCTIONS
β’ Carefully read all instructions and product labels before
beginning installation.
β’ Only mount the heater in a vertical position.
β’ Mount the heater at least 6β above the finished floor.
β’ Do not mount the heater over a bathtub or in a shower stall
enclosure.
β’ When mounted, the heater should not be closer than
12β to an adjacent wall.
β’ Do not block the wall heater β i.e., by mounting under a
towel rack, behind a door, etc.
ELECTRICAL SPECIFICATIONS
NOTE: See wiring label on heater housing. The heater
may be wired for either 120V or 240V operation and
requires a separate circuit.
UNIT DIMENSIONS
Housing: 121/2β high x 101/ 32β wide x 3/8β deep.
Grille: 143
/ 114β high x β wide x 1β deep.
Wall Cutout: 125/ 08β high x 1 5/8β wide.
2
FIGURE 2
MOUNTING THE HOUSING
(New Construction)
Refer to Figure 1.
1. Choose heater location. Make sure the heater will not be
mounted closer than 12β from a vertical surface or 6β
from
the floor.
2. Using nails or screws, mount one side of housing to wall
stud. The flange must be flush to the stud.
3. Run wiring from circuit breaker or fuse box to heater
location.
4. Install box connector into wiring entrance hole in housingβs
junction box.
5. Pull wiring through entrance hole and secure cable to box
connector. Allow 6β of wiring to make connections.
6. Finished wall opening should be 125/8β high x 105/8β wide.
JUNCTION BOX
ROUGH-IN FRAME
WALL
CUTOUT
WALL STUDS
β
10
5
/
8
β
β
β 125/ β 8β
FIGURE 1
EXISTING
CONSTRUCTION
NEW CONSTRUCTION
MOUNTING THE HOUSING
(Existing Construction)
1. Choose heater location. Make sure the heater will not be
mounted closer than 12β from a vertical surface or 6β
from the floor.
2. Refer to Figure 2. Make wall cutout next to a wall stud.
Cutout size: 125/8β high x 105/8β wide.with frame.)
3. Run wiring from circuit breaker or fuse box to heater
location.
4. Install box connector into wiring entrance hole in housingβs
junction box.
5. Pull wiring through cutout and secure cable to box
connector. Allow 6β of wiring to make connections.
6. Refer to Figure 3. Insert TOP of housing into cutout first
so that box connector clears the wall. Then, insert bottom
of housing into cutout. The flange must be flush with the
wall.
7. Use nails or screws to mount one side of housing to wall
stud.
FIGURE 3
WALL STUDS
JUNCTION BOX
HEATER ASSMBLY
FLANGE
MOUNTING
HOLES
ROUGH-IN
BOX
βBβ UNIT MOUNTING HOLE
- TOP AND BOTTOM
INSTALLATION
WARNING: To reduce the risk of fire, do not store or use
gasoline or other flammable vapors and liquids in the
vicinity of the heater.
CAUTION: High temperature, risk of fire, keep electrical
cords, drapery, furnishings, and other combustibles at
least 3 feet (0.9 m) from the front of the heater and away
from the side and rear.
3
WIRING CONNECTIONS
Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
1. While making wiring connections, support the heater
assembly on the bottom of the rough-in frame.
2. For 120 Volt operation, make wiring connections as shown
in Figure 4.
3. For 240 Volt operation, make wiring connections as shown
in Figure 5.
4. Use wire nuts to make connections. Insulate all
connections with electrical tape.
SECURING THE HEATER
1. Dress all wiring back to into junction box.
2. Locate center holes in housing flange and align with
mounting holes in grille.
3. Use two provided screws to attach grille to housing.
4
1
2
3
4
1
2
3
FIGURE 4
FIGURE 5
120vAC
240vAC
GREEN OR BARE
GROUND
GREEN
GROUND
WHITE
BLACK
BLACK
RED
WHITE
YELLOW
120vAC
60HZ
GREEN OR BARE
GROUND
GREEN
GROUND
RED OR WHITE
BLACKBLACK
RED
WHITE
YELLOW
240vAC
60HZ
NO
CONNECTION
NO
CONNECTION
Product Specifications
Brand: | Broan |
Category: | Heater |
Model: | 9815WH |
Do you need help?
If you need help with Broan 9815WH, ask a question below and other users will answer you
Heater Broan User Manuals
26 October 2024
26 October 2024
14 October 2024
Heater User Manuals
- Heater Candy
- Heater Delonghi
- Heater Domo
- Heater Cecotec
- Heater Noveen
- Heater Kogan
- Heater SereneLife
- Heater Olimpia Splendid
- Heater Sencor
- Heater Orava
- Heater Hortus
- Heater EMOS
- Heater Fluval
- Heater Gude
- Heater Ryobi
- Heater Bimar
- Heater Velleman
- Heater Livoo
- Heater Brandson
- Heater Ausclimate
- Heater Ufesa
- Heater Bromic
- Heater Omega Altise
- Heater Adler
- Heater Master
- Heater Einhell
- Heater Eden
- Heater Tristar
- Heater Guardian
- Heater Eldom
- Heater Brentwood
- Heater Chauvet
- Heater Korona
- Heater Stanley
- Heater Big Ass Fans
- Heater Bionaire
- Heater Herschel
- Heater AustWood
- Heater Eurolite
- Heater Kenmore
- Heater Mellerware
- Heater Otsein-Hoover
- Heater Perfect Aire
- Heater LifeSmart
- Heater EvoHeat
- Heater Eurom
- Heater NewAir
- Heater Optimum
- Heater MSW
- Heater Uniprodo
- Heater Yellow Garden Line
- Heater Ravanson
- Heater Sonnenkonig
- Heater United
- Heater Enders
- Heater Mission Air
- Heater Kemlan
- Heater Duro Pro
- Heater Yamazen
- Heater Mestic
- Heater SHX
Latest Heater User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
26 October 2024
26 October 2024
25 October 2024