AFX Plaza PLZS11MBBN Manual
Read below 📖 the manual in Italian for AFX Plaza PLZS11MBBN (1 pages) in the Relief category. This guide has been helpful for 2 people and has been rated 4.5 stars on average by 2 users
Page 1/1
E26 (MB) door Luminaires In
Wall Mount
120VAC / 60Hz
Page 1 of 1 8061339 R1
Model #: PLZS11BN
PLZS11MBBN
311312332
Limited Factory Warranty
AFX Inc. hereby warranty that this xture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5 years
from date of shipment from factory. This warranty covers all component parts and extends only to replacement of defective xture or components; it does not cover failure due
to improper installation, misuse, mishandling or damage incurred in transit.
View shown for reference
only. Individual models may
vary.
Safety Precautions
• Read all safety precautions and installation instructions carefully before installing or servicing this xture. Failure to comply with these instructions
could result in potentially fatal electric shock and/or property damage.
• It is recommended that a qualied electrician perform all wiring. This xture must be wired in accordance with all national and local electrical codes.
• Do not handle any energized xture or attempt to energize any xture with wet hands or while standing on a wet or damp surface or in water.
• This xture is designed for use in a 120 circuit. This xture is not compatible with dimming circuit. VAC
• Make sure that the power source conforms to the requirements of the xture. (See labels on the xture housing).
• reduce the risk of electrical shock, and to assure proper operation, this xture must be adequately grounded. To accomplish proper grounding, To
there must be a separate ground wire (green) contact between this xture and the ground connection of your main power supply panel.
• This xture is intended to be used for general indoor lighting in dry or damp locations.
Assembly Instructions
Step 1 Preparing for installation–
A. Disconnect electrical power at fuse or circuit breaker box before
installing or servicing any part of this xture.
B. Carefully remove the xture from the carton, remove components
from hardware kit.
C. Remove mounting bracket (2) from xture.
D. Install mounting bracket (2) to junction box (not included) securely
with two screws (1).
E. Install the threaded stem (4) to the mounting bracket (2) and
secure it with a nut (3).
Wiring All wiring must take place inside junction box (not –
included).
Caution: Make sure power is o at fuse or circuit breaker box.
Check power wires for damage or scrapes Use wire suitable for .
at least 90°C (194°F). Most dwellings built before 1985 Note:
have supply wire rated to 60°C. Consult a qualied electrician
before installing.
Step 2 Wiring xture –
A. Make all wire connections to appropriate wire. Secure with wire
nuts (8) (provided).
B. Connect the green wire from the xture to the supply power
source ground wire.
C. Connect the black wire from the xture to the black (L) wire from
supply power source.
D. Connect the white wire from the xture to the white (N) wire from
supply power source.
E. Pull on each wire lead to make sure connections are secure.
Make certain no bare wires are exposed outside of wire
connectors. Tuck all connections neatly into the junction box.
Step 3 Mounting –
A. Install the xture housing (5) to the mounting bracket by aligning the middle hole on the housing
with the threaded stem (4) and securing it with the nial (6).
B. Install 2x bulbs (9 not included) to lamp sockets. Use only E26, medium base lamps, Max –60W
Type A- 19.
C. Slide the diuser (7) into the housing (5).
Step 4 Restore power at fuse or circuit breaker box–
Product Specifications
Brand: | AFX |
Category: | Relief |
Model: | Plaza PLZS11MBBN |
Do you need help?
If you need help with AFX Plaza PLZS11MBBN, ask a question below and other users will answer you
Relief AFX User Manuals
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
Relief User Manuals
- Relief Xiaomi
- Relief IKEA
- Relief Philips
- Relief DeWalt
- Relief Hama
- Relief Neewer
- Relief Hazet
- Relief Schwaiger
- Relief Kogan
- Relief Behringer
- Relief GoGEN
- Relief Nitecore
- Relief Kichler
- Relief Integral LED
- Relief Golden Lighting
- Relief ET2
- Relief Quoizel
- Relief Crystorama
- Relief Brennenstuhl
- Relief Varaluz
- Relief Aputure
- Relief Media-tech
- Relief Westinghouse
- Relief Canarm
- Relief Klein Tools
- Relief Schneider
- Relief Dainolite
- Relief Manfrotto
- Relief Fluval
- Relief Ryobi
- Relief Nanlite
- Relief BeamZ
- Relief Steinel
- Relief Maxim
- Relief Nordlux
- Relief Brandson
- Relief Aplic
- Relief CSL
- Relief Bearware
- Relief NUVO
- Relief Sonneman
- Relief Milwaukee
- Relief Generac
- Relief OttLite
- Relief Kern
- Relief Be Cool
- Relief ORNO
- Relief Showtec
- Relief Valerie Objects
- Relief V-Tac
- Relief Wireless Solution
- Relief Infinity
- Relief Elation
- Relief Magmatic
- Relief Chauvet
- Relief Karma
- Relief Weeylite
- Relief Black Diamond
- Relief Lumie
- Relief WAC Lighting
- Relief Eurolite
- Relief Casalux
- Relief Aqara
- Relief Beghelli
- Relief Rosco
- Relief DeSisti
- Relief Astera
- Relief EXO
- Relief Profoto
- Relief GRE
- Relief Ikan
- Relief Impact
- Relief Olight
- Relief Perel
- Relief Blackburn
- Relief Sigma
- Relief Rayzr 7
- Relief Excello
- Relief Genaray
- Relief Altman
- Relief Setti+
- Relief Kanlux
- Relief ARRI
- Relief Osram
- Relief Light4Me
- Relief GlobalTronics
- Relief Lume Cube
- Relief Digipower
- Relief ETC
- Relief Fiilex
- Relief Portman
- Relief ColorKey
- Relief Litepanels
- Relief Perfect Christmans
- Relief XQ-Lite
- Relief Heitronic
- Relief Maxxmee
- Relief Obsidian
- Relief Blizzard
- Relief Amaran
- Relief LUPO
- Relief Enttec
- Relief Fotodiox
- Relief GVM
- Relief Halo
- Relief HQ Power
- Relief Raya
- Relief Smith-Victor
- Relief Zylight
- Relief Light & Motion
- Relief DIO
- Relief COLBOR
- Relief Lucide
- Relief Cineo
- Relief Prolycht
- Relief AD Trend
- Relief Aveo Engineering
- Relief Litegear
- Relief Temde
Latest Relief User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024