LED Indoor Ceiling Luminaires Model # ALDF1318LAJD1GY
Surface Mount ALDF1525LAJD1 GY
120VAC / 60Hz ALDF 32LAJD1 20 GY
Page 1 of 1 8061169 R0
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this xture. Failure to comply with these instructions could result in
potentially fatal electric shock and/or property damage.
It is recommended that a qualied electrician perform all wiring. This xture must be wired in accordance with all national and local electrical codes.
Do not handle any energized xture or attempt to energize any xture with wet hands or while standing on a wet or damp surface or in water.
This xture is designed for use in a 120VAC, 60Hz fused circuit.
To reduce the risk of electrical shock, and to assure proper operation, this xture must be adequately grounded. To accomplish proper grounding, there must be a
separate ground wire (green) contact between this xture and the ground connection of your main power supply panel.
This xture is intended to be used for general door lighting in dry or damp locations.in
Disclaimer
Changes or modications not expressly approved by the party responsible for compliance could void NOTE: This the user’s authority to operate the equipment.
equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-005 (B) / NMB-005
(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modications to this xture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
t may cause undesired operation of the devichat e.
Assembly Instructions
1. Preparing for installation
A. Disconnect electrical power before installing or servicing any part of this
xture
B. Remove xture from carton; remove ceiling pan (4) with shade ) already (6
attached, and hardware kit. Remove the acrylic diuser (7) and set aside.
C. Install two shorter screws (2) to gem bar embossed holes with screws (1)
facing the xture until screw head is ush with gem bar . per Figure 1
D. Attach gem bar (1) to the junction box (not provided) with two long screws (3 ).
2. Wiring
All wiring must take place inside junction box. Caution: Make sure power is o
at fuse or circuit breaker box. Check power wires for damage or scrapes. If power
supply wires are within three inches of v use wire suitable for at least 90°dri er, C
(194F). Most dwellings built before 1985 have supply wire rated to 60°C. Note:
Consult a qualied electrician before installing.
A. This unit will not operate properly unless connected to a “grounded” electrical
circuit. Electrical shock, over heating, low or no light output, and shortened
LED life can result if proper grounding is not done. Securely attach green (or
green and yellow) wire to ground supply wire.
B. Using wire nuts (provided), connect white supply wire to white xture lead. (N)
Connect black (L)) supply wire to black xture lead. Do not mix wires. Pull on
each wire lead to make sure connections are secure. Make certain no bare
wires are exposed outside of wire connectors. Tuck all connections neatly into
junction box.
3. Back pan mounting
A. Align back pan (4) to two screws (2) on round gem bar and secure with two
thumb nuts (5) as shown in Figure 2.
4. Color ChangingTemperature Adjustment, CCT (if desired)
A. Set the two color selection switches in according to the desired color Figure 2,
temperature as shown below. Fixture is preset to 3500K from factory. Note:
5. Mounting diuser
A. Install the acrylic diuser (7) into the shade (6). With the matte nish side of (7) facing down, bend it slightly to angle it up inside the shade as
shown in . Figure 3
B. The diuser should fall into place at the bottom of the shade.
6. Power to the xture can now be restored.
Limited Factory Warranty
AFX Inc. hereby warranty that this xture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5 years from
date of shipment from factory. This warranty covers all component parts and extends only to replacement of defective xture or components; it does not cover failure due to
improper installation, misuse, mishandling or damage incurred in transit.
Product Specifications
Brand: | AFX |
Category: | Relief |
Model: | Ashland ALDF2032LAJD1GY |
Do you need help?
If you need help with AFX Ashland ALDF2032LAJD1GY, ask a question below and other users will answer you
Relief AFX User Manuals
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
13 October 2024
Relief User Manuals
- Relief Xiaomi
- Relief IKEA
- Relief Philips
- Relief DeWalt
- Relief Hama
- Relief Neewer
- Relief Hazet
- Relief Schwaiger
- Relief Kogan
- Relief Behringer
- Relief GoGEN
- Relief Nitecore
- Relief Kichler
- Relief Integral LED
- Relief Golden Lighting
- Relief ET2
- Relief Quoizel
- Relief Crystorama
- Relief Brennenstuhl
- Relief Varaluz
- Relief Aputure
- Relief Media-tech
- Relief Westinghouse
- Relief Canarm
- Relief Klein Tools
- Relief Schneider
- Relief Dainolite
- Relief Manfrotto
- Relief Fluval
- Relief Ryobi
- Relief Nanlite
- Relief BeamZ
- Relief Steinel
- Relief Maxim
- Relief Nordlux
- Relief Brandson
- Relief Aplic
- Relief CSL
- Relief Bearware
- Relief NUVO
- Relief Sonneman
- Relief Milwaukee
- Relief Generac
- Relief OttLite
- Relief Kern
- Relief Be Cool
- Relief ORNO
- Relief Showtec
- Relief Valerie Objects
- Relief V-Tac
- Relief Wireless Solution
- Relief Infinity
- Relief Elation
- Relief Magmatic
- Relief Chauvet
- Relief Karma
- Relief Weeylite
- Relief Black Diamond
- Relief Lumie
- Relief WAC Lighting
- Relief Eurolite
- Relief Casalux
- Relief Aqara
- Relief Beghelli
- Relief Rosco
- Relief DeSisti
- Relief Astera
- Relief EXO
- Relief Profoto
- Relief GRE
- Relief Ikan
- Relief Impact
- Relief Olight
- Relief Perel
- Relief Blackburn
- Relief Sigma
- Relief Rayzr 7
- Relief Excello
- Relief Genaray
- Relief Altman
- Relief Setti+
- Relief Kanlux
- Relief ARRI
- Relief Osram
- Relief Light4Me
- Relief GlobalTronics
- Relief Lume Cube
- Relief Digipower
- Relief ETC
- Relief Fiilex
- Relief Portman
- Relief ColorKey
- Relief Litepanels
- Relief Perfect Christmans
- Relief XQ-Lite
- Relief Heitronic
- Relief Maxxmee
- Relief Obsidian
- Relief Blizzard
- Relief Amaran
- Relief LUPO
- Relief Enttec
- Relief Fotodiox
- Relief GVM
- Relief Halo
- Relief HQ Power
- Relief Raya
- Relief Smith-Victor
- Relief Zylight
- Relief Light & Motion
- Relief DIO
- Relief COLBOR
- Relief Lucide
- Relief Cineo
- Relief Prolycht
- Relief AD Trend
- Relief Aveo Engineering
- Relief Litegear
- Relief Temde
Latest Relief User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024