Page 1/1
User Manual
AMBIENT GAS MEMBRANE THERMOST
Read all the instruction carefully
This thermostats is designed to regulate the temperature in domestic and
industrial environments.
SAFETY WARNINGS
During installation and operation of the device, it is necessary to comply
with the following instructions:
1) The device must be installed by a skilled person, in strict compliance with
the connection diagrams
2) Do not power on or connect the device if any part of it is damaged
3) After installation, inaccessibility to the connection terminals without
appropriate tools must be granted
4) The device must be installed and activated in compliance with current
electric systems standards
5) Before accessing the connection terminals, verify that the leads are not live
Code Model Contact Functions
VE018800 KLIMA 2 NA -
VE019600 KLIMA 3 NA + NC -
VE020400 KLIMA 3L NA + NC Power on warning lamp
VE021200 KLIMA SI NA + NC ON/OFF + Power on warning lamp
VE022000 KLIMA IN NA + NC ON/OFF
VE023800 KLIMA SW NA + NC Summer/Winter
VE024600 KLIMA 2V NA + NC 2 speed + Summer/Winter/OFF
VE268900 KLIMA 3V NA + NC 3 speed + OFF
TECHNICAL SPECIFICATIONS
• Free mounted single-pole mechanical thermostat
• Setting range: +5 / +30°C
• Differential: Δ ≤t 1°C
• Capacity of the contacts: 16(2,5)A 250V ~ for models KLIMA 2 e KLIMA 3
10(1,5)A 250V ~ for models KLIMA 3L, KLIMA SI, KLIMA IN,
KLIMA SW, KLIMA 2V, KLIMA 3V
• Thermal gradient: 1°C / 15 min.
• Sensitive element: vapour expansion lung
• Class I equipment
• Protection degree: IP20
• Type of action: 1B
• Silver contacts 1000/1000
• Break or switching contacts
• Pollution degree: 2 (normal)
• Voltage pulse: 4kV
• Operating temperature: 0 ÷ 40°C
• Operating humidity: 20 ÷ 90 %RH noncondensing
INSTALLATION
The thermostat should be tted at approximately 1.5 m from the ground avoid positioning
it near doors, windows, sources of heat and in places where there is too much or too little
ventilation.
1) The thermostat can be tted directly to the wall or to the ush-mounting box (centre
distance 60 mm).
2) Remove the knob, unscrew the screw of the cover and remove it
3) a) x the base to the wall
b) connect the thermostat earth by using the terminal marked with the earth symbol
c) follow the wiring diagram inside the cover; x the exible inseparable wires to the
relative screw terminals
d) replace the cover, screws and knob.
USER’S GUIDE
1) Set the temperature required by turning the knob;
2) To limit the setting eld:
a) Isolate the power supply line
b) Remove the knob
c) Insert the limit markers in the housing
under the knob (17°C ÷ 23°C
d) Return the knob to its housing.
REFERENCE STANDARDS
Conformity with EU directives: 2014/35/EU (LVD), 2014/30/EU (EMCD)
is declared with reference to the following standard: EN 60730-2-9
DIMENSIONS
ISCOM004-2105 Mod. KLIMA
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
83,7
76,5
82,9
60
60
31
39
CONNECTIONS
KLIMA 2
T
+°C
16(2,5)A 250V~
N
L
KLIMA 3
T
+°C
16(2,5)A 250V~
N
L
KLIMA 3L
T
+°C
10(1,5)A 250V~
N
L
KLIMA IN
ON OFF
T
+°C
N
L
10(1,5)A
250V~
KLIMA SI
ON OFF
T
+°C
N
L
10(1,5)A
250V~
KLIMA SW
T
+°C
N
L
10(1,5)A
250V~
KLIMA 2V
OFF
I
II
T
+°C
N
L
10(1,5)A
250V~
KLIMA 3V
T
+°C
III
OFF
I
II
N
L
10(1,5)A
250V~
Note:
for “heating” operation
mode, remove the cable
terminal which is inside
the device from terminal
3 to teminal 2.
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general
waste at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.
Product Specifications
Brand: | Vemer |
Category: | Thermostat |
Model: | Klima 2V |
Do you need help?
If you need help with Vemer Klima 2V, ask a question below and other users will answer you
Thermostat Vemer User Manuals
18 October 2024
18 October 2024
18 October 2024
18 October 2024
18 October 2024
18 October 2024
18 October 2024
18 October 2024
18 October 2024
18 October 2024
Thermostat User Manuals
- Thermostat ATAG
- Thermostat Bosch
- Thermostat AEG
- Thermostat Siemens
- Thermostat EBERLE
- Thermostat Schwaiger
- Thermostat Oreg
- Thermostat Netatmo
- Thermostat Busch-Jaeger
- Thermostat Danfoss
- Thermostat Schneider
- Thermostat EMOS
- Thermostat Heatit
- Thermostat Dimplex
- Thermostat Velleman
- Thermostat GE
- Thermostat Tru Components
- Thermostat Bearware
- Thermostat Max
- Thermostat Elgato
- Thermostat EVE
- Thermostat ORNO
- Thermostat Avidsen
- Thermostat STI
- Thermostat Hunter
- Thermostat Basetech
- Thermostat TFA
- Thermostat REMKO
- Thermostat Vaillant
- Thermostat Boneco
- Thermostat Grohe
- Thermostat Drayton
- Thermostat Jung
- Thermostat Ambiano
- Thermostat Crestron
- Thermostat Xavax
- Thermostat Remeha
- Thermostat Heatmiser
- Thermostat Hive
- Thermostat GENERAL Life
- Thermostat Silvercrest
- Thermostat HomePilot
- Thermostat Elektrobock
- Thermostat Corberó
- Thermostat Delta Dore
- Thermostat Homematic IP
- Thermostat Vimar
- Thermostat Emerson
- Thermostat Salus
- Thermostat Fenix
- Thermostat Baxi
- Thermostat Honeywell
- Thermostat Google
- Thermostat Enda
- Thermostat Emko
- Thermostat Wachendorff
- Thermostat Elro
- Thermostat De Dietrich
- Thermostat Theben
- Thermostat Computherm
- Thermostat Grasslin
- Thermostat Niko
- Thermostat H-Tronic
- Thermostat Gira
- Thermostat Fantini Cosmi
- Thermostat Radson
- Thermostat Junkers
- Thermostat Buderus
- Thermostat Viessmann
- Thermostat Tado
- Thermostat Amfra
- Thermostat Aube
- Thermostat Eneco
- Thermostat Orbis
- Thermostat Emmeti
- Thermostat Optima
- Thermostat Drayton Erie
- Thermostat Carrier
- Thermostat Eurotronic
- Thermostat PECO
- Thermostat Intertechno
- Thermostat Maico
- Thermostat Frico
- Thermostat Bulex
- Thermostat Gewiss
- Thermostat Etherma
- Thermostat Horstmann
- Thermostat Plugwise
- Thermostat Mikoterm
- Thermostat Cepra
- Thermostat ChiliTec
- Thermostat King
- Thermostat Sygonix
- Thermostat Landis Gyr
- Thermostat Saunier Duval
- Thermostat Itho-Daalderop
- Thermostat Finder
- Thermostat ICY
- Thermostat THERMAFLEX
- Thermostat Rose LM
- Thermostat Seitron
- Thermostat IMIT
- Thermostat Watts
- Thermostat Nefit
- Thermostat Econo-Heat
- Thermostat EQ3
- Thermostat Ferroli
- Thermostat Hager
- Thermostat Otio
- Thermostat Jumo
- Thermostat EQ-3
- Thermostat Magnum
- Thermostat Webasto
- Thermostat UPM
- Thermostat Eqiva
- Thermostat Johnson Control
- Thermostat Devi
- Thermostat Tylö
- Thermostat AWB
- Thermostat ELKO
- Thermostat Yokis
- Thermostat Technoline
- Thermostat 2Heat
- Thermostat RWE
- Thermostat ACV
- Thermostat Plieger
- Thermostat Veria
- Thermostat Wallair
- Thermostat Stiebel Eltron
- Thermostat Trotec
- Thermostat Hugo Muller
- Thermostat VDH
- Thermostat Ouellet
- Thermostat Nest
- Thermostat Innogy
- Thermostat Devolo
- Thermostat Zehnder
- Thermostat Go Green
- Thermostat EasyTemp
- Thermostat Levica
- Thermostat Coati
- Thermostat Berker
- Thermostat MundoControl
Latest Thermostat User Manuals
25 October 2024
25 October 2024
25 October 2024
25 October 2024
25 October 2024
25 October 2024
25 October 2024
25 October 2024
25 October 2024
25 October 2024