Samsung AM120AXVCNH Manual
Samsung
Air conditioning
AM120AXVCNH
Read below π the manual in Italian for Samsung AM120AXVCNH (23 pages) in the Air conditioning category. This guide has been helpful for 2 people and has been rated 4.5 stars on average by 2 users
Page 1/23
Air conditioner
Installation manual
AM***AXV***
β’ Thank you for purchasing this Samsung air conditioner.
β’ Before operating this unit, please read this installation manual carefully and retain it for future
reference.
DB68-11525A-03
2English
Contents
Safety Information 3
Safety Information 3
Installation Procedure 5
Preparations for Outdoor Unit 5
Choosing the installation location 7
Preparing materials and tools 9
Outdoor unit installation 9
Refrigerant pipe installation 13
Electrical wiring work 28
Air tightness test and vacuum drying 36
Pipe insulation 38
Refrigerant charging 41
Basic segment display 42
Setting outdoor unit option switch and key function 42
Performing final checks and trial operation 50
Appendix 52
Inspection and trial operation 52
Automatic refrigerant amount detection function 54
Technical specifications 55
MEMO 57
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger,
headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent
possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from
other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for
details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product
and its electronic accessories should not be mixed with other commercial wastes for disposal.
3
English
Safety Information
Please follow the following safety information for safety of the
installer and the user.
β’ DVM S2 air conditioner uses R-410A refrigerant.
β When using R-410A, moisture or foreign substances may
affect the performance and reliability of the product.
Safety precautions must be obeyed when installing the
refrigerant pipe.
β The designed maximum pressure of the system is 4.1MPa
and therefore select appropriate material and thickness
according to the regulations.
β R-410A is a quasi-azeotrope of two refrigerants and it has
to be charged in liquid phase when filling the refrigerant.
(If you charge vapor refrigerant, it may change the blend of
the refrigerant and cause product malfunction.)
β’ You must connect the indoor units for R-410A refrigerant.
Refer to product catalog to find out the models names for
connectable indoor units. (If you connect the indoor units that
are not designed for R-410A, it cannot operated normally.)
β’ After completing the installation and trial operation, explain to
the user how to use and maintain the product. Also, hand over
this installation manual so that it can be stored by the user.
β’ Manufacturer is not responsible for the incidents occurred by
improper installation. Installer is responsible for any installation
related claims from the user occurred by neglecting warnings
and cautions stated in this manual. (Installer will be responsible
for any service charges that may occur)
β’ Generally, system air conditioners should not be relocated
after installation. But when it has to be relocated for inevitable
reasons, please contact Samsungβs qualified dealers for system
air conditioners.
WARNING
β’ Hazards or unsafe practices that may result in severe personal
injury or death.
CAUTION
β’ Hazards or unsafe practices that may result in minor personal
injury (to installer/user) or property damage.
General information
WARNING
β’ Consult qualified installer or dealer for installation.
β When installation is done by unqualified person, problems
such as water leakage, electric shock or fire may occur.
β’ Installation work must be done properly according to this
installation manual.
β When installation is not done properly, it may cause water
leakage, electric shock or fire.
β’ When installing the unit in a small room, take measure to keep
the refrigerant concentration from exceeding allowable safety
limits in case of refrigerant leakage. Consult the dealer for
precautionary measure before the installation.
β When refrigerant leaks and exceed dangerous
concentration level, it may cause suffocation accidents.
β’ If any gas or impurities, except R-410A refrigerant, come into
the refrigerant pipe, serious problem may occur and it may
cause injury.
β’ Use the supplied accessories, specified components and tools
for the installation.
β Do not use the pipe and the installation product used for
refrigerants except R-410A.
β Failure to use the specified components can cause product
fall down, water leakage, electrical shock, and fire. (The
pipe and flare components used for refrigerants except
R-410A must not be used)
β’ Install the outdoor unit on a hard and even place that can
support its weight.
β If the place cannot support its weight, the outdoor unit may
fall down and it may cause injury.
β’ Check the following before installation and service work.
β Before welding, remove dangerous and inflammable things
that may cause an explosion and fire around the work.
β Before welding, remove the refrigerant from inside the
pipe or the product.
β If you perform welding while refrigerant is in the pipe, it
may increase the pressure of the refrigerant and cause
the pipe to burst. If the pipe bursts or explodes, it may
cause severe injury to the installer.
β When welding, use the nitrogen gas to eliminate oxidation
inside the pipe.
β’ Do not modify the product on your own.
β Potential risk of electric shock, fire, product failure or injury.
β’ Fix the outdoor unit securely on foundation to resist strong
wind or earthquake.
β If the outdoor unit is not properly fixed, it turns over and
accidents may occur.
β’ Electric work must be done by qualified persons, complying
the national wiring regulations and installed according to the
instruction stated in the installation manual with leased circuit.
β Capacity shortage on the leased circuit and improper
installation may cause electric shock or fire.
β’ Make sure to perform grounding work.
β Do not connect the ground wire to a gas pipe, water pipe,
lightning rod or telephone grounding. Improper grounding
could cause electric shock.
β’ Wiring must be connected with the designated wires and it
must be fixed securely so that it does not apply any external
force to the connection part of the terminals.
β If connection for fixation is not properly done, it may cause
heat generation or fire.
β’ Neatly arrange the wires in the electrical parts to make sure
that electrical cover is closed securely without any gaps.
β If the cover is not properly closed, heat may generate on
the electrical terminal and cause electric shock or fire.
β’ Exclusive circuit breaker (MCCB, ELB) must be installed to the
power supply.
β When overcurrent or current leakage occurs with no circuit
breaker installed, power will not be cut-off and it may
cause electric shock or fire.
β Do not use damaged parts. It may cause fire or electric shock.
β’ You must cut-off the power before you work on, or adjust any
power supply part for product installation, maintenance, repair
or any other services.
β There is risk of electric shock.
β Even when the power is off, it is dangerous when you come
in contact with inverter PCB, fan PCB since high pressure
DC voltage is charged to those parts.
Safety Information
Product Specifications
Brand: | Samsung |
Category: | Air conditioning |
Model: | AM120AXVCNH |
Do you need help?
If you need help with Samsung AM120AXVCNH, ask a question below and other users will answer you
Air conditioning Samsung User Manuals
24 October 2024
19 October 2024
15 October 2024
15 October 2024
15 October 2024
15 October 2024
14 October 2024
14 October 2024
14 October 2024
13 October 2024
Air conditioning User Manuals
- Air conditioning Candy
- Air conditioning Electrolux
- Air conditioning LG
- Air conditioning Panasonic
- Air conditioning Delonghi
- Air conditioning Koldfront
- Air conditioning Arcelik
- Air conditioning Danby
- Air conditioning Hisense
- Air conditioning Gree
- Air conditioning TCL
- Air conditioning Hotpoint
- Air conditioning Whirlpool
- Air conditioning Cecotec
- Air conditioning Comfee
- Air conditioning Kogan
- Air conditioning SereneLife
- Air conditioning Create
- Air conditioning Midea
- Air conditioning Sauber
- Air conditioning Haier
- Air conditioning Olimpia Splendid
- Air conditioning Westinghouse
- Air conditioning Sencor
- Air conditioning Electroline
- Air conditioning Fujitsu
- Air conditioning Orava
- Air conditioning Mistral
- Air conditioning Khind
- Air conditioning Amana
- Air conditioning Dimplex
- Air conditioning Whynter
- Air conditioning GE
- Air conditioning Hitachi
- Air conditioning Hyundai
- Air conditioning VΓ€nEE
- Air conditioning Daikin
- Air conditioning Be Cool
- Air conditioning Avidsen
- Air conditioning Mitsubishi
- Air conditioning Friedrich
- Air conditioning Tristar
- Air conditioning Dometic
- Air conditioning Eldom
- Air conditioning Elba
- Air conditioning Philco
- Air conditioning Black And Decker
- Air conditioning Wilfa
- Air conditioning Heinner
- Air conditioning SEEGER
- Air conditioning IFB
- Air conditioning Duracraft
- Air conditioning Home Electric
- Air conditioning Milectric
- Air conditioning LERAN
- Air conditioning Perfect Aire
- Air conditioning Argoclima
- Air conditioning ARCTIC WIND
- Air conditioning Trisa
- Air conditioning Daizuki
- Air conditioning Mayer
- Air conditioning Be Quiet!
- Air conditioning BOSFOR
- Air conditioning KDK
- Air conditioning Aconatic
- Air conditioning AireMax
- Air conditioning Profile
- Air conditioning Keystone
- Air conditioning Honeywell
- Air conditioning Ravanson
- Air conditioning ActronAir
- Air conditioning Woods
- Air conditioning Aspes
- Air conditioning Fuave
- Air conditioning Yamazen
- Air conditioning Cool-Space
- Air conditioning GoldAir
- Air conditioning KuulAire
- Air conditioning SHE
- Air conditioning BLUEPALM
Latest Air conditioning User Manuals
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
27 October 2024
26 October 2024
26 October 2024