Lego NINJAGO 71820 Manual
Read below π the manual in Italian for Lego NINJAGO 71820 (4 pages) in the Toys category. This guide has been helpful for 4 people and has been rated 4.5 stars on average by 2 users
Page 1/4
KC-C Reels
Safety Warnings and Operation
For use with the DLRO2
User Guide
1. WARNING
These warnings must be read and understood before use:
ξThe lead set is intended only for use with the Megger DLRO2; it must not
be used with other measuring instruments
ξRead the safety warnings provided with the DLRO2 before use
ξBefore use, inspect the lead set for wear and damage. Probes, wires
and connectors must be in good order, clean and dry with no broken or
cracked insulation
ξDamaged lead sets must NOT be used
ξThe lead set is rated only for connection to low voltage circuits: <30 V at a
maximum of 2 A
ξThe safe connection rating is that of the lowest rated item in the
measurement circuit which comprises instrument, probe assembly and
accessories
ξDo NOT connect this lead set to mains circuits
ξThe lead set is rated for indoor and outdoor use
ξOperating environment between 0 Β°C and +50 Β°C, <95% RH
ξThe safe altitude for use is β€3,000 m above sea level
ξIf the lead set is used in a manner not speciο¬ed by the manufacturer, the
protection provided by the test lead may be impaired
ξMass: KC100C: 7.6 kg. KC50C and KC50E: 4.4 kg
www.megger.com 2
WARNING
2. Operation
ξThis test lead is intended for use with a Megger DLRO2 to measure
bonded conductors. For example, the resistance of lightning receptors to
earth for large equipment in production, or in-situ during commissioning
or maintenance, or following repair
ξThe KC series enable construction of long test leads in 50 m increments
suitable for testing large structures.
ξA test lead will consist of the appropriate instrument connector and asset
clips at each end of a KC50C (50 m) or KC100C (100 m) lead. One or two
KC50E (50 m) extension leads may be added to the assembly to extend the
length.
ξFor assemblies using more than one cable, the KC50E extension reel
should be unwound and removed from its drum ο¬rst: lift the extension
cable connector from the slot in the drum and pass it though the hole in
the drum wall. Connect the extension to the next cable to be unwound
and repeat the process.
ξEnsure that 4 mm test terminals are correctly connected to the DLRO2:
mating red to red and black to black
ξAll tests must be carried out in accordance with the equipment
manufacturersβ procedures and test limits
ξBefore testing tall structures, ensure that any static potential is fully
discharged by connecting an additional ground wire to the installed
lightning protection cable at the base of the structure
ξWhen working with tall structures, consider the risks from carrying heavy
equipment and unreeling cables at height. Arrange a safe procedure to
protect those working below and at height during setting-up, testing and
removing the test connections, especially when bad weather, high winds
or precipitation add to the risk
www.megger.com 3
Operation
Product Specifications
Brand: | Lego |
Category: | Toys |
Model: | NINJAGO 71820 |
Do you need help?
If you need help with Lego NINJAGO 71820, ask a question below and other users will answer you
Toys Lego User Manuals
26 October 2024
26 October 2024
26 October 2024
26 October 2024
26 October 2024
26 October 2024
25 October 2024
25 October 2024
24 October 2024
24 October 2024
Toys User Manuals
- Toys IKEA
- Toys Kogan
- Toys GoGEN
- Toys Hasbro
- Toys Mega Bloks
- Toys Chipolino
- Toys Backyard Discovery
- Toys Valley Dynamo
- Toys Bullet
- Toys Pardini
- Toys Biltema
- Toys Alpha
- Toys Atomik
- Toys Huffy
Latest Toys User Manuals
27 October 2024
27 October 2024
26 October 2024
26 October 2024
24 October 2024
24 October 2024
23 October 2024
23 October 2024
23 October 2024
23 October 2024