The Round®
Check package contents:
• Thermostat
• Wallanchors&screws(2each)
Before you begin, make sure
you have:
• No.2Phillips&smallpocketscrewdrivers
• Hammer
• Level(optional)
• Pencil
• Drillandbit(3/16”fordrywall,7/32”
forplaster)
MERCURY NOTICE
Ifthisproductisreplacingacontrolthatcontainsmercuryinasealedtube,donot
placetheoldcontrolinthetrash.Contactyourlocalwastemanagementauthorityfor
instructions regarding recycling and proper disposal.
CAUTION: ELECTRICAL HAZARD
Cancauseelectricalshockorequipmentdamage.Disconnectpowerbefore
beginninginstallation.
Must be installed by a trained, experienced technician
Readtheseinstructionscarefully.Failuretofollowtheseinstructions
can damage the product or cause a hazardous condition.
Pre-installation checklist
Thismanualcoversthefollowingmodels:
ThisthermostatcontainsaLithiumbatterywhichmaycontainPerchloratematerial.
Perchlorate Material—special handling may apply,
Seewww.dtsc.ca.gov/hazardouswaste/perchlorate
• Heat-only • HeatandCoolT87K T87N
T87N/T87K • Owner's Manual
69-1958EFS—02 2
System Types
• Gasoroilheat( )T87K
• Gas,oil,orelectricheatwithair
conditioning( )T87N
• Warmair,hotwater,high-efficiency
furnaces,heatpumps,steam,gravity
• Heatonly
• Heatonlywithfan( )T87N
• Heatonly,2-wire,and3-wirehot-water
valve(poweropenandclosevalves)
( )T87K
• Coolonly( )T87N
System Settings (T87N)
• Heat,Off,Cool
Fan Settings (T87N)
• Auto,On
Specifications
Temperature Range
• 40°to90°F(4.5°to32°C)
Shipping Temperature
• -20°to120°F(-28.9°to48.9°C)
Operating Relative Humidity
• 5%to90%(non-condensing)
Electrical Ratings
• Voltage:20–30VAC
• Runningcurrent:0.02–1.0A
Installthethermostatabout5feet(1.5m)abovethefloorinanarea
with good air circulation at average temperature.
Do not install in locations where the thermostat can be affected by:
• Draftsordeadspotsbehinddoorsandincorners
• Hotorcoldairfromducts
• Sunlightorradiantheatfromappliances
• Concealedpipesorchimneys
• Unheated/uncooledareassuchasanoutsidewallbehindthethermostat
NO
NO NO
Installation tips
Product application
Thisthermostatprovideselectroniccontrolof:
• 24VACheatingsystems( )T87K
• 24VACheatingandcoolingsystems( )T87N
English: Français : Español: Page 1 Page 6 • Página 11
3 69-1958EFS—02
1. Pull wires through wire
hole. Position wallplate on
wall, level, and mark hole
positions.
2. Drillholes(3/16”fordrywall,
7/32”forplaster)andtapin
supplied wall anchors.
3. Pullwirethroughwallplate,
position over anchors, then
insert and tighten mounting
screws.Checklevelif
desired.
1. Loosenscrewterminals,insertwiresintoterminalblock,thenre-tightenscrews.
2. Pushexcesswirebackintothewallopening.
3. Plugthewallopeningwithnonflammableinsulationtopreventdraftsfromaffecting
thermostat operation.
Wiring
NOTES
R & Rc terminals (T87N)
Insingle-transformersystem,leavemetal
jumperinplacebetween &R Rc. Remove
metaljumperiftwo-transformersystem.
Heat pump systems (T87N)
Ifwiringtoaheatpump,useasmallpiece
ofwire(notsupplied)toconnectterminalsW
and Y.
Wire specifications
Use18-gaugethermostatwire.Shieldedcable
is not required.
Wallplate installation
Terminal Designations—T87N
W Heat relay.
Y Compressor contactor.
G Fanrelay.
O Heat pump changeover valve
energized in cooling.
Rc Cooling power. Connect to secondary
sideofcoolingsystemtransformer.
R Heating power. Connect to secondary
sideofheatingsystemtransformer.
B Heat pump changeover valve
energized in heating.
Terminal Designations—T87K
W Heat relay.
R Power.Connecttosecondarysideof
heatingsystemtransformer.
Y Thisterminalcanbeusedforsome3-
wirehot-watervalvesystems(power
openandclosevalves).
R
W
Y

Product Specifications

Brand: Honeywell
Category: Thermostat
Model: The Round T87N

Do you need help?

If you need help with Honeywell The Round T87N, ask a question below and other users will answer you




Thermostat Honeywell User Manuals

Thermostat User Manuals

Latest Thermostat User Manuals

Heatmiser

Heatmiser PRT-ETS Manual

25 October 2024
Heatmiser

Heatmiser PRT-W Manual

25 October 2024
Heatmiser

Heatmiser PRTHW Manual

25 October 2024
Heatmiser

Heatmiser PRT-EWTS Manual

25 October 2024
Heatmiser

Heatmiser DT-N Manual

25 October 2024
Heatmiser

Heatmiser DT-EW Manual

25 October 2024
Heatmiser

Heatmiser PRTHW-WTS Manual

25 October 2024
Heatmiser

Heatmiser PRT-RPTS Manual

25 October 2024
Heatmiser

Heatmiser PRT-RP Manual

25 October 2024
Heatmiser

Heatmiser PRT-B Manual

25 October 2024